Product Details
| Model | G1329A 1100 Series |
| Brand | AGILENT |
| Category | Autosamplers |
| Posted | 16.02.2026 |
| Views | 233 |
Used AGILENT G1329A 1100 Series
Condition:: Used
Shipping from::
USA
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
Specifications:
Autosampler (Chiller Compatible)
GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
Injection range: 1– 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)
Replicate injections: 1– 99 from one vial
Precision:
Typically < 0.5 % RSD of peak areas from 5 – 100 µl
Typically < 1 % RSD of peak areas from 1 – 5 µl
Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
Carryover: Typically < 0.1 %, < 0.05 % with external needle cleaning
Sample viscosity range: 2 – 50 cp
Replicate injections per vial: 1 – 99
Sample capacity:
100 × 2-ml vials in 1 tray
40 × 2-ml vials in ½ tray
15 × 6-ml vials in ½ tray (Agilent vials only)
Injection cycle time: Typically 50 s depending on draw speed and injection volume
Can be sold as an individual component or as part of a complete stack
Autosampler (Chiller Compatible)
GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
Injection range: 1– 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)
Replicate injections: 1– 99 from one vial
Precision:
Typically < 0.5 % RSD of peak areas from 5 – 100 µl
Typically < 1 % RSD of peak areas from 1 – 5 µl
Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
Carryover: Typically < 0.1 %, < 0.05 % with external needle cleaning
Sample viscosity range: 2 – 50 cp
Replicate injections per vial: 1 – 99
Sample capacity:
100 × 2-ml vials in 1 tray
40 × 2-ml vials in ½ tray
15 × 6-ml vials in ½ tray (Agilent vials only)
Injection cycle time: Typically 50 s depending on draw speed and injection volume
Can be sold as an individual component or as part of a complete stack