- FDA
- Yes
- CE
- Yes
- ISO13485
- Yes
- GMP
- Yes
- Transport Monitor
- Yes
- Portable monitors
- Yes
- Physiology monitors
- Yes
- Oscillographic monitors
- Yes
- Modular monitors
- Yes
- Intensive care monitors
- Yes
- Home care monitors
- Yes
- Hemodynamic monitors
- Yes
- Monitors for telemedicine
- Yes
- Monitors for research
- Yes
- Monitors for patient visit
- Yes
- Pain management monitors
- Yes
- Nursing homes monitors
- Yes
- Monitors for humans
- Yes
- Monitors for hospitals
- Yes
- Monitors for cardiology
- Yes
- Monitors for animals
- Yes
- Floor-standing monitors
- Yes
- Emergency monitors
- Yes
- Compact monitors
- Yes
- Clinical monitors
- Yes
- Anesthesia monitors
- Yes
- Ambulatory monitors
- Yes
Refurbished PHILIPS SureSigns VS4
Condition:: Refurbished
Shipping from::
USA
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
Features:
Versatile vital signs monitoring with the flexibility to choose between NBP interval mode and spot check mode.
Intuitive touch-screen interface with tools like QuickCapture and QuickCheck for simplifying clinician workflow.
Wireless capability and proactive monitoring tool QuickAlert support Rapid Response teams.
Compatible with existing networks for easy integration.
Touch screen with color LED backlight.
Internal WiFi/802.11 a/b/g option.
Programmable 2D barcode scanner for multiple ID fields.
Time-sync with hospital or network clock.
Improved battery management with visible charging indicator.
Clearly identifiable one-touch NBP on/off button.
Stores up to 800 patient records.
Specifications:
Dimensions:
Size: W: 26 cm (10.2), H: 22 cm (8.6), D: 14.5 cm (5.7)
Weight: 3.1 kg (6.9 lb) – excluding optional recorder
Screen:
4 SVGA TFT-AM LCD display
Resolution: 800 active pixels/line, 600 active lines per frame
Viewing angle: ±60 degrees
NBP (Non-invasive Blood Pressure):
Oscillometric using stepwise deflation pressure
Adult Measurement Range:
Systolic: 30–270 mmHg (4.0–36.0 kPa)
Diastolic: 10 –245 mmHg (1.3–32.7 kPa)
MAP: 20–225 mmHg (2.7–34.0 kPa)
Pediatric Measurement Range:
Systolic: 30–180 mmHg (4.0–24.0 kPa)
Diastolic: 10–150 mmHg (1.3–20.0 kPa)
MAP: 20–160 mmHg (2.7–21.3 kPa)
Neonatal Measurement Range:
Systolic: 30–130 mmHg (4.0–17.0 kPa)
Diastolic: 10–100 mmHg (1.3–13.3 kPa)
MAP: 20–120 mmHg (2.7–16.0 kPa)
Accuracy:
Maximum Standard Deviation: 8 mmHg
Maximum Mean Error: ±5 mmHg
SpO2:
Measurement Range: 0–100%
Pulse Rate Measurement Range: 30–300 bpm
Accuracy: Depends on Sensor
Temperature:
Welch Allyn Predictive:
Modes: Predictive and Monitored
Probe Sites: Oral, Rectal, or Axillary
Range: 26.7–43.3°C (80–110°F)
Accuracy: ±0.1°C (±0.2°F) in monitoring mode
Covidien Tympanic:
Probe Sites: Oral, Rectal, or Axillary
Range: 33°C–42.0°C (91.4°F–107.6°F)
Accuracy: ±0.2°C (36.7–38.9)
Measurement response time: ≤2 seconds
Battery:
Lithium-ion: 10.8–11.1V (with a 202 form factor)
Operating time: 4 hours with NBP every 15 minutes.
Data Output:
HL7 format, via Ethernet port
Serial data
Patient Type:
Adult, Pediatric, Neonatal
Versatile vital signs monitoring with the flexibility to choose between NBP interval mode and spot check mode.
Intuitive touch-screen interface with tools like QuickCapture and QuickCheck for simplifying clinician workflow.
Wireless capability and proactive monitoring tool QuickAlert support Rapid Response teams.
Compatible with existing networks for easy integration.
Touch screen with color LED backlight.
Internal WiFi/802.11 a/b/g option.
Programmable 2D barcode scanner for multiple ID fields.
Time-sync with hospital or network clock.
Improved battery management with visible charging indicator.
Clearly identifiable one-touch NBP on/off button.
Stores up to 800 patient records.
Specifications:
Dimensions:
Size: W: 26 cm (10.2), H: 22 cm (8.6), D: 14.5 cm (5.7)
Weight: 3.1 kg (6.9 lb) – excluding optional recorder
Screen:
4 SVGA TFT-AM LCD display
Resolution: 800 active pixels/line, 600 active lines per frame
Viewing angle: ±60 degrees
NBP (Non-invasive Blood Pressure):
Oscillometric using stepwise deflation pressure
Adult Measurement Range:
Systolic: 30–270 mmHg (4.0–36.0 kPa)
Diastolic: 10 –245 mmHg (1.3–32.7 kPa)
MAP: 20–225 mmHg (2.7–34.0 kPa)
Pediatric Measurement Range:
Systolic: 30–180 mmHg (4.0–24.0 kPa)
Diastolic: 10–150 mmHg (1.3–20.0 kPa)
MAP: 20–160 mmHg (2.7–21.3 kPa)
Neonatal Measurement Range:
Systolic: 30–130 mmHg (4.0–17.0 kPa)
Diastolic: 10–100 mmHg (1.3–13.3 kPa)
MAP: 20–120 mmHg (2.7–16.0 kPa)
Accuracy:
Maximum Standard Deviation: 8 mmHg
Maximum Mean Error: ±5 mmHg
SpO2:
Measurement Range: 0–100%
Pulse Rate Measurement Range: 30–300 bpm
Accuracy: Depends on Sensor
Temperature:
Welch Allyn Predictive:
Modes: Predictive and Monitored
Probe Sites: Oral, Rectal, or Axillary
Range: 26.7–43.3°C (80–110°F)
Accuracy: ±0.1°C (±0.2°F) in monitoring mode
Covidien Tympanic:
Probe Sites: Oral, Rectal, or Axillary
Range: 33°C–42.0°C (91.4°F–107.6°F)
Accuracy: ±0.2°C (36.7–38.9)
Measurement response time: ≤2 seconds
Battery:
Lithium-ion: 10.8–11.1V (with a 202 form factor)
Operating time: 4 hours with NBP every 15 minutes.
Data Output:
HL7 format, via Ethernet port
Serial data
Patient Type:
Adult, Pediatric, Neonatal