Product Details
| Model | IGD-03 |
| Brand | DIATHERA |
| Category | Tonometers |
| Posted | 03.12.2025 |
| Views | 1043 |
New DIATHERA IGD-03
(plus shipping costs and VAT)
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
Description
The principle of operation of the IGD-03 diathera indicator is based on the magnetodynamic method of generating a dosed movement impulse to a moving rod interacting with the elastic surface of the eye through the eyelid, and subsequent processing of its speed function (dynamic impact on the eye with a certain kinetic energy through the eyelid in the sclera area):
-
Fundamental changes in the methodology.
-
Ease of procedure.
-
High reliability of results.
-
Now a single measurement and no difficulties with the vertical!
The new IGD-03 diathera devices retained all the advantages of measuring IOP through the eyelid in the sclera zone.
Evaluate the benefits of the new indicator IGD-03 diathera:
-
A single measurement is sufficient to obtain a reliable digital value (according to Maklakov with a load of 10 g).
-
The measuring rod is always in working position.
-
A slight deviation of the device from the vertical does not reduce the reliability of the results.
Why do doctors choose transpalpebral diathera indicators?
-
Devices save time and allow you to examine a larger number of patients.
-
Possibility of application in difficult clinical cases: with contraindications to corneal tonometry, with allergies to anesthetics.
-
There is no risk of patient infection, sterilization is not required, it is enough to carry out disinfection.
-
It is possible to measure IOP both in the patient's "lying" position and in the "sitting" position.
-
There is no need to conduct pachymetry, because. the measurement takes place in the area of the sclera, not the cornea.
How do patients tolerate the procedure?
-
The procedure is fast, safe and painless.
-
Corrective lenses are not an obstacle for tonometry.
-
Children do not have a sense of fear of research.
Specifications:
Measurement of tonometric IOP according to Maklakov at a load of: 10 g Permissible deviation of the limit value estimate (26 mmHg) between normal and high pressure: ± 2.0 mm Hg Time of one measurement no more than: 1s Supply voltage: 3V Battery type: AAA Number of measurement cycles on one set of batteries: not less than 5000 Service life, years: not less than 5 Weight: 105g Overall dimensions: 176x26x20mm
Shipping & Handling
Items located in Poland, Europe.
Your order will be sent in 1 buisness days by UPS Worldwide Express.
Typical shipping time:
USA, Europe, UK: 2 - 5 days.
We also deliver almost all over the world, the average delivery time to other countries: 3 - 6 days.
Please contact us if you have additional questions!
Have a nice day!
Didn’t find what you were looking for? Place your own ad on the Bimedis platform
Place your advert on Bimedis and reach buyers worldwide.