Used THERMO SCIENTIFIC Evolution 220
Condition:: Used
Shipping from::
USA
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
Empower your analysis and bring versatility and productivity to your lab with the Thermo Scientific Evolution 220 UV-Vis system. For routine to research analysis, this instrument series offers real innovations that provide enhanced usability and performance – without added complexity. With straightforward software, cutting-edge instrumentation and a wide selection of accessories, the Evolution 220 system works with you to perform experiments the way you want – for the results you need.
Performance Specifications:
Optical Design: Double-beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-TurnerMonochromator
Spectral bandwidths: Variable: 1.0 nm; 2.0 nm; AFBG Microcell optimized; AFBG Fiber optic optimized; AFBG Materials optimized
Light source: Xenon Flash Lamp
Detector: Dual Silicon Photodiodes
Scan ordinate modes: Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Wavelength: Range: 190-100 nm; Accuracy: ±0.5 nm (541.9, 546.1 nm mercury lines) ±0.8 nm (full range 190–1100 nm); Repeatability: ≤0.05 nm (546.1 nm mercury line, SD of 10 measurements)
Scanning speed: 3.5 A; Display Range: -0.3 to 4.0 A; Accuracy – Instrument: 1A: ±0.004 A, 2A: ±0.008 A, Measured at 440 nm using neutral density filters traceable to NIST; Noise: 0A: ≤0.00015 A 1A: ≤0.00025 A 2A: ≤0.00080 A 260 nm, 1.0 nm SBW, RMS; Drift (Stability):
Performance Specifications:
Optical Design: Double-beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-TurnerMonochromator
Spectral bandwidths: Variable: 1.0 nm; 2.0 nm; AFBG Microcell optimized; AFBG Fiber optic optimized; AFBG Materials optimized
Light source: Xenon Flash Lamp
Detector: Dual Silicon Photodiodes
Scan ordinate modes: Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Wavelength: Range: 190-100 nm; Accuracy: ±0.5 nm (541.9, 546.1 nm mercury lines) ±0.8 nm (full range 190–1100 nm); Repeatability: ≤0.05 nm (546.1 nm mercury line, SD of 10 measurements)
Scanning speed: 3.5 A; Display Range: -0.3 to 4.0 A; Accuracy – Instrument: 1A: ±0.004 A, 2A: ±0.008 A, Measured at 440 nm using neutral density filters traceable to NIST; Noise: 0A: ≤0.00015 A 1A: ≤0.00025 A 2A: ≤0.00080 A 260 nm, 1.0 nm SBW, RMS; Drift (Stability):