Product Details
| Model | QuantGene 9600 |
| Brand | BIOER |
| Category | PCR Thermal Cycler |
| Posted | 23.02.2026 |
| Views | 324 |
Product Specifications
- Real-time PCR Thermal Cycler
- Yes
- Gradient PCR Thermal Cycler
- Yes
- Incubation PCR Thermal Cycler
- Yes
- Fluorescence PCR Thermal Cycler
- Yes
Used BIOER QuantGene 9600
Condition:: Used
Availability:: In stock
Shipping from::
United Kingdom
Description
This listing is for the Bioer Quant Gene 9600 Fluorescent Quantitative Detection System
The unit is in full working condition and is ready for immediate use
Bioer LineGene Plus 9600 FQD-96A – Fluorescent Quantitative Detection System
Key Specifications
Sample Capacity: 96-well 0.2 mL PCR plates, 12 × 8-strip tubes, or 96 × 0.2 mL single tubes (transparent bottom)
Reaction Volume: 5–100 µL
Dynamic Range: 1–10¹⁰ copies/µL
Detection Channels: 5 or 6 channels (F1–F6)
Excitation Wavelength: 300–800 nm
Emission Wavelength: 500–800 nm
Temperature Range: 4–105°C (0.1°C increments)
Temperature Control Accuracy: ±0.1°C
Temperature Uniformity: ≤ ±0.3°C
Heating Rate: Up to 4.0°C/s
Cooling Rate: Up to 4.0°C/s
Hot Lid Temperature Range: 30–110°C (adjustable, default 105°C)
Gradient Temperature Range: 1–36°C
Scanning Mode: Full-plate scanning and designated line scanning (5.5 seconds per scan)
Programming: Up to 20 segments per program, up to 99 cycles
Operating System Compatibility: Windows 7/8/10
Software Requirements: Microsoft Excel 2000/2002/2003/2007/2012
Minimum Computer Configuration: RAM: 512 MB; Hard Disk: 10 GB; CPU: Pentium 4; Virtual Memory: ≥1000 MB
Power Supply: 100–240V, 50/60Hz, 600W
Dimensions: 410 mm (W) × 386 mm (D) × 352 mm (H)
Weight: Approximately 20 kg
Certifications: CE, EMC, RoHS2.0, MET
The unit is in full working condition and is ready for immediate use
Bioer LineGene Plus 9600 FQD-96A – Fluorescent Quantitative Detection System
Key Specifications
Sample Capacity: 96-well 0.2 mL PCR plates, 12 × 8-strip tubes, or 96 × 0.2 mL single tubes (transparent bottom)
Reaction Volume: 5–100 µL
Dynamic Range: 1–10¹⁰ copies/µL
Detection Channels: 5 or 6 channels (F1–F6)
Excitation Wavelength: 300–800 nm
Emission Wavelength: 500–800 nm
Temperature Range: 4–105°C (0.1°C increments)
Temperature Control Accuracy: ±0.1°C
Temperature Uniformity: ≤ ±0.3°C
Heating Rate: Up to 4.0°C/s
Cooling Rate: Up to 4.0°C/s
Hot Lid Temperature Range: 30–110°C (adjustable, default 105°C)
Gradient Temperature Range: 1–36°C
Scanning Mode: Full-plate scanning and designated line scanning (5.5 seconds per scan)
Programming: Up to 20 segments per program, up to 99 cycles
Operating System Compatibility: Windows 7/8/10
Software Requirements: Microsoft Excel 2000/2002/2003/2007/2012
Minimum Computer Configuration: RAM: 512 MB; Hard Disk: 10 GB; CPU: Pentium 4; Virtual Memory: ≥1000 MB
Power Supply: 100–240V, 50/60Hz, 600W
Dimensions: 410 mm (W) × 386 mm (D) × 352 mm (H)
Weight: Approximately 20 kg
Certifications: CE, EMC, RoHS2.0, MET