Product Details
| Model | Dinamap Pro 400V2 |
| Brand | GE |
| Category | Patient monitors |
| Posted | 19.02.2026 |
| Views | 202 |
Refurbished GE Dinamap Pro 400V2
Condition:: Refurbished
Shipping from::
USA
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
Features:
Designed to provide accurate and reliable vital sign measurements.
Advanced blood pressure monitoring system.
Measures NIBP, SpO2, temperature, and heart rate.
Includes pole mount for convenient installation.
Comes with new battery, SpO2 sensor, NIBP hose, oral temperature sensor, and two new cuffs.
Completely refurbished and biomedical inspected.
Specifications:
Dimensions:
Height: 9.8 in (25 cm)
Width: 9.8 in (25 cm)
Depth: 6.9 in (17.5 cm)
Weight: 7.8 lbs (3.5 kg)
Power Requirements:
Mains Protection against electrical shock: Class 1
AC Input: 115/230 VAC, 50/60 Hz (nominal)
Voltage: 9063 Hz (range)
Alternate Sources Protection against electrical shock: Class 1
DC Input Voltage: 18-24 VDC, 30 VA from supplied power converter
External DC Input Fuse: Internal, Auto-resetting
Battery: 12-volt, 2.3 amp-hours. Protected by auto-resetting fuse. Minimum operation time: 2 hours (5-minute auto cycle with an adult cuff at 25°C (77°F) from a full charge. Time for full recharge: 1 hr 50 min from full discharge when the Monitor is switched off and 8 hrs when the Monitor is switched on.
Environmental:
Operating Temperature: +5° C to +40° C (+41° F to +104° F)
Operating Atmospheric Pressure: 700 hPa to 1060 hPa
Storage Temperature: -20° C to +50° C (-4° F to +122° F)
Storage/Transportation Atmospheric Pressure: 500 hPa to 1060 hPa
Humidity Range: 0% to 95%, non-condensing
Radio Frequency:
Complies with IEC Publication 601-1-2 (April 1993) Medical Electrical Equipment, Electromagnetic Compatibility Requirements and Tests and CISPR 11 (Group 1, Class A) for radiated and conducted emissions.
Designed to provide accurate and reliable vital sign measurements.
Advanced blood pressure monitoring system.
Measures NIBP, SpO2, temperature, and heart rate.
Includes pole mount for convenient installation.
Comes with new battery, SpO2 sensor, NIBP hose, oral temperature sensor, and two new cuffs.
Completely refurbished and biomedical inspected.
Specifications:
Dimensions:
Height: 9.8 in (25 cm)
Width: 9.8 in (25 cm)
Depth: 6.9 in (17.5 cm)
Weight: 7.8 lbs (3.5 kg)
Power Requirements:
Mains Protection against electrical shock: Class 1
AC Input: 115/230 VAC, 50/60 Hz (nominal)
Voltage: 9063 Hz (range)
Alternate Sources Protection against electrical shock: Class 1
DC Input Voltage: 18-24 VDC, 30 VA from supplied power converter
External DC Input Fuse: Internal, Auto-resetting
Battery: 12-volt, 2.3 amp-hours. Protected by auto-resetting fuse. Minimum operation time: 2 hours (5-minute auto cycle with an adult cuff at 25°C (77°F) from a full charge. Time for full recharge: 1 hr 50 min from full discharge when the Monitor is switched off and 8 hrs when the Monitor is switched on.
Environmental:
Operating Temperature: +5° C to +40° C (+41° F to +104° F)
Operating Atmospheric Pressure: 700 hPa to 1060 hPa
Storage Temperature: -20° C to +50° C (-4° F to +122° F)
Storage/Transportation Atmospheric Pressure: 500 hPa to 1060 hPa
Humidity Range: 0% to 95%, non-condensing
Radio Frequency:
Complies with IEC Publication 601-1-2 (April 1993) Medical Electrical Equipment, Electromagnetic Compatibility Requirements and Tests and CISPR 11 (Group 1, Class A) for radiated and conducted emissions.