Product Details
| Model | Infinity Gamma XL |
| Brand | DRAGER |
| Category | Patient monitors |
| Posted | 19.02.2026 |
| Views | 172 |
Refurbished DRAGER Infinity Gamma XL
Condition:: Refurbished
Shipping from::
USA
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
Features:
The Dräger Infinity Gamma XL is a multiparameter patient monitor suitable for monitoring various parameters including ECG, arrhythmia analysis, respiratory, SpO2, pulse rate, patient temperature, non-invasive and invasive blood pressure.
It is designed to be used as both a bedside patient monitor and a transport monitor for neonates, pediatric, and adult patients.
Features an 8-inch color screen display capable of showing up to four channels simultaneously.
Compact and portable design with Dräger’s patented Pick and Go technology.
Standard parameters include ECG, basic arrhythmia, respiration, pulse rate, temperature, noninvasive blood pressure, and SpO2.
Scalable feature set designed to meet the needs of mid-acuity care.
Supports a wireless card offering enhanced security (WPA2) and Wi-Fi (820.11g) technology for wider bandwidth.
Can operate as a standalone device or as part of the Infinity Network.
Seamless wired-to-wireless networking ensures consistent data acquisition without interruptions.
Dräger Infinity Gamma XL Specifications:
Monitoring Capabilities:
Suitable for neonatal, pediatric, and adult applications.
Dimensions:
Height: 8.5 inches (215 mm)
Width: 11.9 inches (301 mm)
Depth: 5.2 inches (131 mm)
Weight: 7.32 lbs. (3.32 kg) without battery
ECG:
Available leads: 3-lead set (Leads: I, II, III), 5-lead set (Leads: I, II, III, aVR, aVL, aVF, V), 6-lead set (Leads: I, II, III, aVR, aVL, aVF, V, V+)
Measuring range: 15 to 300 bpm
Accuracy: ± 5 bpm or ± 2% (whichever is greater)
Respiration:
Sensing lead: II
Measuring method: Impedance pneumography
Measuring range: 0 to 155 breaths/min
Accuracy: ± 1 l/min or ± 2% (whichever is greater)
Pulse Oximetry (SpO2):
Measuring method: Absorption spectrophotometry
Measuring range: 15 to 300 bpm
Accuracy: SpO2: 70 to 100% ± 2%, Pulse: ± 3 bpm or ± 3% (whichever is less)
Temperature:
Measuring range: 0 to 50°C
Accuracy: Probe: ± 0.1°C, System: ± 0.2°C
Noninvasive Blood Pressure (NBP):
Displayed parameters: Systolic, mean, and diastolic pressures
Measuring method: Oscillometric utilizing step deflation
Measuring range: Adult, pediatric, and neonatal ranges specified
Cuff pressure specifications provided for different patient categories
Connector:
Quick-release connector with single airway.
The Dräger Infinity Gamma XL is a multiparameter patient monitor suitable for monitoring various parameters including ECG, arrhythmia analysis, respiratory, SpO2, pulse rate, patient temperature, non-invasive and invasive blood pressure.
It is designed to be used as both a bedside patient monitor and a transport monitor for neonates, pediatric, and adult patients.
Features an 8-inch color screen display capable of showing up to four channels simultaneously.
Compact and portable design with Dräger’s patented Pick and Go technology.
Standard parameters include ECG, basic arrhythmia, respiration, pulse rate, temperature, noninvasive blood pressure, and SpO2.
Scalable feature set designed to meet the needs of mid-acuity care.
Supports a wireless card offering enhanced security (WPA2) and Wi-Fi (820.11g) technology for wider bandwidth.
Can operate as a standalone device or as part of the Infinity Network.
Seamless wired-to-wireless networking ensures consistent data acquisition without interruptions.
Dräger Infinity Gamma XL Specifications:
Monitoring Capabilities:
Suitable for neonatal, pediatric, and adult applications.
Dimensions:
Height: 8.5 inches (215 mm)
Width: 11.9 inches (301 mm)
Depth: 5.2 inches (131 mm)
Weight: 7.32 lbs. (3.32 kg) without battery
ECG:
Available leads: 3-lead set (Leads: I, II, III), 5-lead set (Leads: I, II, III, aVR, aVL, aVF, V), 6-lead set (Leads: I, II, III, aVR, aVL, aVF, V, V+)
Measuring range: 15 to 300 bpm
Accuracy: ± 5 bpm or ± 2% (whichever is greater)
Respiration:
Sensing lead: II
Measuring method: Impedance pneumography
Measuring range: 0 to 155 breaths/min
Accuracy: ± 1 l/min or ± 2% (whichever is greater)
Pulse Oximetry (SpO2):
Measuring method: Absorption spectrophotometry
Measuring range: 15 to 300 bpm
Accuracy: SpO2: 70 to 100% ± 2%, Pulse: ± 3 bpm or ± 3% (whichever is less)
Temperature:
Measuring range: 0 to 50°C
Accuracy: Probe: ± 0.1°C, System: ± 0.2°C
Noninvasive Blood Pressure (NBP):
Displayed parameters: Systolic, mean, and diastolic pressures
Measuring method: Oscillometric utilizing step deflation
Measuring range: Adult, pediatric, and neonatal ranges specified
Cuff pressure specifications provided for different patient categories
Connector:
Quick-release connector with single airway.