
Product Details
| Model | iFusion |
| Brand | OPTOVUE |
| Category | Optical coherence tomography |
| Posted | 24.02.2026 |
| Views | 237 |
Product Specifications
- Scan speed, A-scans per second
- 26000
- Scan depth, mm
- 2-2.3
- Shooting angle
- 21° (H) x 21° (V)
- Working distance, mm
- 15
- Minimal pupil diameter, mm
- 2.5
- Weight (kg)
- 36
- Overall dimensions, cm ⓘ
- 48.6х87.4х66.9
Refurbished OPTOVUE iFusion
Condition:: Refurbished
Warranty (month):: 12
Availability:: In stock
Shipping from::
USA
19 985
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
OPTOVUE IFUSION 2 - IVUE 2 + ICAM + ERGONOMIC TABLE + WIN 10
We are committed to ensuring our customers’ satisfaction. So here you get more than you came to get. Our policy is OVER-DELIVER! With a differentiated infrastructure and a highly qualified team, composed of technicians and engineers trained in accordance with the highest standards required by manufacturers, We are committed to excellence, development and continuous evolution of its services.
Excellent Cosmetic condition! (no scratches)
Excellent Body condition! (no dents/scratches)
Very tiny cosmetic signs may be visible when viewed very closely Fully Functional Condition! Exceeds 80% of service life
This is a RENEWED unit!! It's in excellent mechanical and cosmetic condition!!
What does it include:
- One year Warranty in the entire USA (no additional cost)
- Icam
- Fixation
- Keyboard & Mouse
- Desktop
- Table - Manual on USB drive
- Professional packing
- Windows 10
DESCRIPTION:
Optovue iFusion combines the best of Spectral-Domain OCT capabilities of iVue and high-quality imaging from iCam on a single, integrated, versatile platform that will add value to your practice.
Optovue iFusion OCT combines iVue ‘s advanced OCT capabilities with iCam, a high-performance fundus camera that delivers anterior and posterior segment images with exceptional depth, color, and resolution. The system software is very simple and intuitive and allows quick and flexible image review. With iFusion, you can quickly superimpose iVue OCT images onto background images. Thanks to iFusion, therefore, you save time and space for greater efficiency in patient management.
The Optovue iFusion can measure retinal thickness, display interactive 3-D images, perform Nerve Fiber and Ganglion Cell measurements, and perform Retinal Photography. This allows Dr. Kelly to examine your eye health at the cell-layer level for the early detection of Glaucoma, Macular Degeneration, and Diabetes. The imaging system performs year-to-year comparisons to detect changes much sooner than conventional means.
Optovue iFusion Features
Introducing Epithelial Thickness Mapping
Vault mapping
Advanced GCC imaging
iWellnessExam
Retinal mapping and analysis
Optic disc and RNFL assessment
Comprehensive anterior segment analysis
3D and En Face imaging
iCam fundus camera
Easy to use software
Technical specifications
Scanner OCT Image : 80,000 A-scan/second
Depth Resolution (in tissue) : 5.0μm
Traverse Resolution : 15μm (retina)
Scan Range Depth : 2 – 2.3mm (retina)
Scan Beam Wavelength : 840nm (+/-10nm)
OCT Fundus Image (En Face) : FOV 12mm(H) x 9mm(V)
Minimum Pupil Diameter : 2.5mm
External Image (Live IR) FOV : 13mm x 9mm
Table Dimensions (in) : (W) 19.1 x (L) 34.4 x (H) 263-343
Networking specifications
Operating System : Windows 7, 8 and 10; 65-bit OS compatible
Processor Speed : 3.0 GHz; Intel Quad Core (desktop); Core 2 (laptop)
Network Bandwidth : 1 Gbps or higher
Computer RAM : 4 GB or higher
Monitor Resolution : 1920 x 1080 at 32-bit
iCam12Non- Mydriatic Fundus Camera
45° color and red−free imaging
12−megapixel camera for high-fidelity color saturation
Multi-visit view provides a visit-to-visit comparison
Three-color display offers varying perspectives of the fundus while the emboss feature creates a 3D-like view for new insights into retinal health
Overlay feature to superimpose OCT images onto the fundus photo
External color photography documents conditions of the ocular surface
We are committed to ensuring our customers’ satisfaction. So here you get more than you came to get. Our policy is OVER-DELIVER! With a differentiated infrastructure and a highly qualified team, composed of technicians and engineers trained in accordance with the highest standards required by manufacturers, We are committed to excellence, development and continuous evolution of its services.
Excellent Cosmetic condition! (no scratches)
Excellent Body condition! (no dents/scratches)
Very tiny cosmetic signs may be visible when viewed very closely Fully Functional Condition! Exceeds 80% of service life
This is a RENEWED unit!! It's in excellent mechanical and cosmetic condition!!
What does it include:
- One year Warranty in the entire USA (no additional cost)
- Icam
- Fixation
- Keyboard & Mouse
- Desktop
- Table - Manual on USB drive
- Professional packing
- Windows 10
DESCRIPTION:
Optovue iFusion combines the best of Spectral-Domain OCT capabilities of iVue and high-quality imaging from iCam on a single, integrated, versatile platform that will add value to your practice.
Optovue iFusion OCT combines iVue ‘s advanced OCT capabilities with iCam, a high-performance fundus camera that delivers anterior and posterior segment images with exceptional depth, color, and resolution. The system software is very simple and intuitive and allows quick and flexible image review. With iFusion, you can quickly superimpose iVue OCT images onto background images. Thanks to iFusion, therefore, you save time and space for greater efficiency in patient management.
The Optovue iFusion can measure retinal thickness, display interactive 3-D images, perform Nerve Fiber and Ganglion Cell measurements, and perform Retinal Photography. This allows Dr. Kelly to examine your eye health at the cell-layer level for the early detection of Glaucoma, Macular Degeneration, and Diabetes. The imaging system performs year-to-year comparisons to detect changes much sooner than conventional means.
Optovue iFusion Features
Introducing Epithelial Thickness Mapping
Vault mapping
Advanced GCC imaging
iWellnessExam
Retinal mapping and analysis
Optic disc and RNFL assessment
Comprehensive anterior segment analysis
3D and En Face imaging
iCam fundus camera
Easy to use software
Technical specifications
Scanner OCT Image : 80,000 A-scan/second
Depth Resolution (in tissue) : 5.0μm
Traverse Resolution : 15μm (retina)
Scan Range Depth : 2 – 2.3mm (retina)
Scan Beam Wavelength : 840nm (+/-10nm)
OCT Fundus Image (En Face) : FOV 12mm(H) x 9mm(V)
Minimum Pupil Diameter : 2.5mm
External Image (Live IR) FOV : 13mm x 9mm
Table Dimensions (in) : (W) 19.1 x (L) 34.4 x (H) 263-343
Networking specifications
Operating System : Windows 7, 8 and 10; 65-bit OS compatible
Processor Speed : 3.0 GHz; Intel Quad Core (desktop); Core 2 (laptop)
Network Bandwidth : 1 Gbps or higher
Computer RAM : 4 GB or higher
Monitor Resolution : 1920 x 1080 at 32-bit
iCam12Non- Mydriatic Fundus Camera
45° color and red−free imaging
12−megapixel camera for high-fidelity color saturation
Multi-visit view provides a visit-to-visit comparison
Three-color display offers varying perspectives of the fundus while the emboss feature creates a 3D-like view for new insights into retinal health
Overlay feature to superimpose OCT images onto the fundus photo
External color photography documents conditions of the ocular surface
Didn’t find what you were looking for? Place your own ad on the Bimedis platform
Place your advert on Bimedis and reach buyers worldwide.