Bimedis

Product Details

ModelHumphrey FDT 710
BrandZEISS
CategoryOphthalmic perimeters
Posted02.02.2026
Views255

Product Specifications

Test field of view, °
30
Perimeter type
Static computer
Stimulus duration, msec
0.3
Illumination level
100 cd/m2
Weight (kg)
8.6
Overall dimensions, cm
25х48х43

Used ZEISS Humphrey FDT 710


Condition:: Used
Availability:: In stock
Shipping from:: France

6 754

(plus shipping costs and VAT)

Price in seller currency:: 5 860 EUR



Seller:

trustpremiumapproved

France

The Business Centre Medical (CAM)<br/>In a space of 2000 m2, with more than 7,000 articles are presented, stored, inspected, refurbished or reconditioned.<br/>Our offer covers all the needs of the profession, at all levels : equipment and medical devices, of course, but also technical equipment and furniture, for offices, clinics or hospitals.<br/>Why pay more ?<br/>The Business Centre Medical (CAM), is a company specialized in the sale of all types of equipment, medical, of which the common denominator is that they are for sale at discount prices. To meet this economic criteria, CAM responds to the needs for the two divisions :<br/>Department of new equipment<br/>Department equipment refurbished

Description

Key features of the FDT visual field instrument include: • Supra-threshold screening tests in less than 1 minute per eye • Threshold tests in approximately 4 minutes per eye • Easy to use; no special training is required / minimal operator instruction • No correction (trial) lens required; Patients can wear their own correction or none at all (must only be within 6D of the patients refraction) • No eye correction needed for the (untested) opposite eye - it is automatically occluded • Unaffected by ambient lighting - can be used in normal room lighting • Unaffected by pupil size (as small as 2 mm) • Extensive built-in normative age reference database • World-class clinical validation by leading researchers in the field • Software upgrade capability for future improvements Instrument Dimensions: 25 cm [10] wide x 48 cm [19] deep x 43 cm [17] high Electrical Connection: 320-IEC standard power input connector for worldwide use Computer Interface: RS-232 Serial D 9-pin male connector, null-modem cable, Operating Conditions Storage and Shipping Conditions Testing Strategies Test: • 20° Supra-Threshold (C-20 SCREENING - 1) • 20° Supra-Threshold (C-20 SCREENING - 5) • 20° Supra-Threshold (N-30 SCREENING - 1) • 20° Supra-Threshold (N-30 SCREENING - 5) Testing Threshold Strategies: • 20° Threshold (C-20 THRESHOLD) • 30° Nasal Threshold (N-30 THRESHOLD) • MONSTERS computer automated stair thresholding procedure • Stair completion consists of at least four stair repeats, with upper and lower stair limits within 0.3 log10 units of each other. • MONSTERS threshold is calculated as the average of the last upper and lower presentations meeting the stair completion criteria. Reliability indices: • 3 capture trials in C-20 and N-30 screening tests • 6 capture trials in C-20 and N-30 threshold tests • False positive capture trials: • 6 capture trials in C-20 threshold test • 8 capture trials in N-30 threshold test • False negative capture trials: • 0 dB contrast capture trial (~100%) • 3 capture trials in C-20 threshold test • 5 capture trials in N-30 threshold test Stimulus:
• 17 or 19 FDT patterns as well as fixation capture trial patterns OD and OS (4 patterns per visual field quadrant plus a 5° central radius pattern) Screening Test Results: • Deviation field with 4 qualitative loss classifications (within normal limits, slight relative loss, moderate relative loss, severe loss) based on age-related normative references • Reliability indices: fixation and capture ratios of false positive trials Test Threshold Results: • Threshold (dB) Plot • Deviation field with 5 probability level classifications (P ≥ 5%, P < 5%, P < 2%, P < 1%, P < 0.5%) based on age-related normative references • MD (mean deviation) and PSD (Patient of Standard Deviation) global statistics Index values ​​with 5 probability level classifications (P ≥ 5%, P < 5%, P < 2%, P < 1%, P < 0.5%)

Didn’t find what you were looking for? Place your own ad on the Bimedis platform

Place your advert on Bimedis and reach buyers worldwide.

SELL

Related searches