Radiant heater
Yes
Stability of macro-environment
Yes
Access to the child on three sides
Yes
Humidity control
Yes
Lighting level control
Yes
Sound and temperature level control
Yes
Incubator type
Transformer incubator

Used GE Giraffe OmniBed


Condition:: Used
Availability:: In stock
Shipping from:: France

1 816

(plus shipping costs and VAT)

Price in seller currency:: 1 575 EUR



Seller:

trustpremiumapproved

France

The Business Centre Medical (CAM)<br/>In a space of 2000 m2, with more than 7,000 articles are presented, stored, inspected, refurbished or reconditioned.<br/>Our offer covers all the needs of the profession, at all levels : equipment and medical devices, of course, but also technical equipment and furniture, for offices, clinics or hospitals.<br/>Why pay more ?<br/>The Business Centre Medical (CAM), is a company specialized in the sale of all types of equipment, medical, of which the common denominator is that they are for sale at discount prices. To meet this economic criteria, CAM responds to the needs for the two divisions :<br/>Department of new equipment<br/>Department equipment refurbished

Description

The General Electric Giraffe OmniBed is an advanced medical device designed for neonatal intensive care. It combines the functions of an incubator and a warming bed, providing a controlled environment for premature or sick newborns. The Giraffe OmniBed allows for precise adjustment of temperature, humidity, and oxygen, ensuring an optimal environment for babies development. Its ergonomic design facilitates access for care and medical interventions, while minimizing stress for the newborn.
USER COMMAND PARAMETERS
• (Servo)control of newborn temperature: 35 to 37.5°C in 0.1° increments
(regulates the infants temperature whether the bed is in open or closed mode)
• Manual control of radiation power: 0 to 100% in 5% increments
• Humidity Servo Control Range: 30 to 95% relative humidity in 5% increments System Performance
• Expected Life: This device is expected to last at least seven years under normal use, provided it is operated and maintained in accordance with the instructions in the supplied manuals. This life can be extended by regular maintenance and proper repairs, as long as replacement parts are available.
• Closed bed performance, incubator mode: Measurement accuracy at patient level: ±0°C between 30° and 42°C
• Oxygen servo control performance
• Ramp-up time: