Bimedis

Product Details

ModelS-Scan 0.25T
BrandESAOTE
CategoryMRI machines
Posted04.02.2026
Views757

Product Specifications

Magnetic field strength, T
0.25
MRI Type
open
Maximum patient weight (kg)
200
Type of magnet
permanent
Minimum requirements to the premises, square metre
18
Gantry aperture (mm)
330
Max. gradient amplitude (mT/m)
25
Line of sight, cm
25

Used - Like New ESAOTE S-Scan 0.25T


Condition:: Used - Like New
Year:: 2013
Availability:: In stock
Shipping from:: Israel

Safe deal

Bimedis secures your payment until you confirm the equipment is received.

Description

like NEW system, Esaote S Scan Brio 2013, s/w BRIO 1.3C, Coils: LWS Coil, Shoulder Coil DPA, Solenoid Shoulder Coil, HWS Coil with Flexion Extension Functionality, DPA-Knee Coil, DPA Wrist/Hand Coil, DPA OSG Coil, Flexible coil.
SW Sequences: Multi Planar Scout, Spin Echo T1 (SET1), Spin Echo (SET2), Multi Echo (SE_PD_T2), Inversion recovery (IR), Short T1 Inversion Recovery (STIR,STIR T2 S, STIR T2 A), Spin Echo half Echo (SET1HE), Spin Echo half Scan (SET1 HF), Turbo SE T2 weighted (TSE, TSE S), Turbo ME (TME), Gradient Echo (GE, GET2, GET2FC), Short Time inversion recovery Gradient Echo (GE-STIR), Gradient Echo 3D (T3D_T1), Speed Spin Echo T2 (SSE-SET2,SSE-SET2S, SSE-SET2 SA, SSE-SET2 SP), Speed Spin Echo (SSE-SET2 #1), Speed Spin Echo (SSE-SET2 #2), Speed Spin Echo (SSE-SET2 #3), FSE T1, FSE T2, FSE STIR, X-BONE, 3D Steady State Sequences: HYCE, SHARC, SST1, SST2, Real Time
Computer: Pentium Core 2 Quad processor with 4 GB and 160 GB Harddisk to save around 100.000 images (Matrix: 256 x 256)
Return Policy
Items are sold as-is with no returns or refunds available unless explicitly stated.

Didn’t find what you were looking for? Place your own ad on the Bimedis platform

Place your advert on Bimedis and reach buyers worldwide.

SELL

Related searches