Product Details
| Model | 825-UVC |
| Brand | PLAS-LABS |
| Category | Laboratory fume hoods |
| Posted | 16.02.2026 |
| Views | 247 |
New PLAS-LABS 825-UVC
Condition:: New
Shipping from::
USA
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
This chamber has been designed to help improve the accuracy of P.C.R. and general Tissue Culture procedures. The chamber is a still air enclosure which contains both fluorescent and U.V. germicidal lamps. The U.V. system is rated at 254 nm and will decontaminate all surfaces of the interior. The front viewing panel is .500 (13 mm) thick optically clear material. It is extremely effective for protection against 32P labeled compounds. It is very effective against Beta Rays but not Gamma rays. Front plate is replaceable. The doors are removable therefore do not take up valuable laboratory counter workspace.
Specifications:
825-UVA:
Internal Dimensions: 23.5high x 17long x 21high
External Dimensions: 24w x 18d x 28h
825-PCR/HEPA/Exp
Internal Dimensions: 23.5w x 17d x 21h
External Dimensions: 24w x 18d x 28h
Two bright white acrylic shelves are included (5 x 23) & (7 x 23) one is tooled to store pipettors.
Front panel is .500 (l’3 mm) thick for Beta Ray protection
Side access panels are removable.
Proximity sensors turn off the U.V. system for safety when the door is opened
Domestic electric power requirements are 110-115 Volt, 60 Hz. 220 volt units are available.
The system has a two (2) Amp circuit breaker.
Sides and back wall are one piece formed of .375 thick acrylic for long term rigidity, durability, and protection.
Bottom tray has a formed in place spill tray.
Main housing and top are removable for installation of large pieces of research equipment.
The U.V. system is rated at 254 nm. Replacement UV light: EL1122
HEPA ONLY:
Positive pressure external fan (blower). 115-120 Volts.
Small H.E.P.A. filter rated at 99.97% efficiency at 0.3 microns
No tools required for filter change over.
Low fan noise level. Rated at less than 40 dBA
Specifications:
825-UVA:
Internal Dimensions: 23.5high x 17long x 21high
External Dimensions: 24w x 18d x 28h
825-PCR/HEPA/Exp
Internal Dimensions: 23.5w x 17d x 21h
External Dimensions: 24w x 18d x 28h
Two bright white acrylic shelves are included (5 x 23) & (7 x 23) one is tooled to store pipettors.
Front panel is .500 (l’3 mm) thick for Beta Ray protection
Side access panels are removable.
Proximity sensors turn off the U.V. system for safety when the door is opened
Domestic electric power requirements are 110-115 Volt, 60 Hz. 220 volt units are available.
The system has a two (2) Amp circuit breaker.
Sides and back wall are one piece formed of .375 thick acrylic for long term rigidity, durability, and protection.
Bottom tray has a formed in place spill tray.
Main housing and top are removable for installation of large pieces of research equipment.
The U.V. system is rated at 254 nm. Replacement UV light: EL1122
HEPA ONLY:
Positive pressure external fan (blower). 115-120 Volts.
Small H.E.P.A. filter rated at 99.97% efficiency at 0.3 microns
No tools required for filter change over.
Low fan noise level. Rated at less than 40 dBA