Product Details
| Model | Alaris PCU 8015 |
| Brand | BD |
| Category | IV infusion pumps |
| Posted | 19.02.2026 |
| Views | 249 |
Product Specifications
- Insulin infusion
- Yes
- Syringe
- Yes
- Ambulatory
- Yes
- PCA
- Yes
Refurbished BD Alaris PCU 8015
Condition:: Refurbished
Shipping from::
USA
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
The CareFusion Alaris 8015 PC Unit serves as the core component of the Alaris System, providing a common interface for programming infusions and monitoring.
It utilizes a color display to clearly communicate critical information such as programming, infusion status, and hospital-defined policies.
Wireless connectivity facilitates seamless communication between the Alaris System and the Alaris Systems Manager.
Supports Guardrails Suite MX with Guardrails Point-Of-Care software and v9 Operating System software.
Enables integration with existing network infrastructure for enhanced data management and analytics.Alaris Infusion Pump Specifications:
Dimensions:
Height: 8.8 In (22.4 cm)
Width: 6.9 In (17.5 cm)
Depth: 9 In (22.9 cm)
Weight: 7.2 lb (3.2 kg)
Battery:
Battery run time varies based on module activity and number of attached modules.
With a new, fully charged battery, operational times include:
6 Hours: with one Pump module infusing at 25 mL/h
3 Hours: with four Pump modules infusing at 25 mL/h
5 Hours: with one active SpO2 module
6 Hours: with one Syringe module or PCA module infusing at 5 mL/h
3 Hours: with four Syringe modules, or one PCA module and three Syringe modules, infusing at 5 mL/h
4 Hours: with one active EtCO2 module
Communication Data Port: RS-232 with an RJ45 connector
Memory:
Stores system configuration/data set, operating software, events, errors, and battery logs.
Compact flash memory stores application software, DataSet, and hex files data for operating system software.
On-board flash memory contains software needed to initialize the Alaris 8105 System.
It utilizes a color display to clearly communicate critical information such as programming, infusion status, and hospital-defined policies.
Wireless connectivity facilitates seamless communication between the Alaris System and the Alaris Systems Manager.
Supports Guardrails Suite MX with Guardrails Point-Of-Care software and v9 Operating System software.
Enables integration with existing network infrastructure for enhanced data management and analytics.Alaris Infusion Pump Specifications:
Dimensions:
Height: 8.8 In (22.4 cm)
Width: 6.9 In (17.5 cm)
Depth: 9 In (22.9 cm)
Weight: 7.2 lb (3.2 kg)
Battery:
Battery run time varies based on module activity and number of attached modules.
With a new, fully charged battery, operational times include:
6 Hours: with one Pump module infusing at 25 mL/h
3 Hours: with four Pump modules infusing at 25 mL/h
5 Hours: with one active SpO2 module
6 Hours: with one Syringe module or PCA module infusing at 5 mL/h
3 Hours: with four Syringe modules, or one PCA module and three Syringe modules, infusing at 5 mL/h
4 Hours: with one active EtCO2 module
Communication Data Port: RS-232 with an RJ45 connector
Memory:
Stores system configuration/data set, operating software, events, errors, and battery logs.
Compact flash memory stores application software, DataSet, and hex files data for operating system software.
On-board flash memory contains software needed to initialize the Alaris 8105 System.
Didn’t find what you were looking for? Place your own ad on the Bimedis platform
Place your advert on Bimedis and reach buyers worldwide.