Bimedis

Product Details

ModelColleague
BrandBAXTER
CategoryIV infusion pumps
Posted07.11.2025
Views281

Product Specifications

Insulin infusion
Yes
Syringe
Yes
Ambulatory
Yes
PCA
Yes

Used - Good BAXTER Colleague


Condition:: Used - Good
Year:: 2008
Availability:: In stock
Shipping from:: Canada
Sales area:: Afghanistan, Albania, Algeria

170

Safe deal

Bimedis secures your payment until you confirm the equipment is received.

Description

BAXTER COLLEAGUE CXE VOLUMETRIC INFUSION PUMP

AS SHOWN IN PICTURES THE SCREEN HAS A SMALL DENT BUT EVERYTHING ON THIS UNIT STILL WORKS PERFECTLY.

Below is a detailed (though not absolutely exhaustive) specification and feature breakdown for the Baxter COLLEAGUE CXE (model codes 2M91617 / 2M91637 etc.) volumetric infusion pump, compiled from available operator’s manuals and reference sources. If you want a specific variant (single?channel vs triple?channel, or regional edition), I can pull up those details too.

General / Product Identity

ItemDescription

Product familyBaxter COLLEAGUE CXE volumetric infusion pump ManualsLib 2ManualsLib 2

Model / product codes2M91617, 2M91637 (and variants like 2M91617A, 2M91637A) pi Veterinary Consultants 3ManualsLib 3ManualsLib 3

ChannelsAvailable as single?channel (COLLEAGUE CXE) and triple?channel (COLLEAGUE 3 CXE) versions medwrench.com 3ManualsLib 3ManualsLib 3

Intended useFor controlled delivery of fluids, medications, infusions (IV, intra-arterial, subcutaneous, etc.), including continuous or intermittent delivery pi Veterinary Consultants 2ManualsLib 2

Physical & Environmental Specifications

ParameterValue / Range

Dimensions (H × W × D)~ 10.0 in × 7.75 in × 7.75 in (? 254 × 197 × 197 mm) (excluding clamp knob or power cord) Ardus Medical 4dreveterinary.com 4ManualsLib 4

Weight~ 10.4 lb (~?4.7 kg) for the single channel version dreveterinary.com 2ManualsLib 2 Triple?channel version weight ~ 7.9 kg (? 17.5 lb) including mounting clamp ManualsLib 2ManualsLib 2

Operating temperature15 °C to 38 °C (59 °F to 100 °F) ManualsLib 2ManualsLib 2

Relative humidity (operating)20% to 95% non?condensing ManualsLib 1

Barometric pressure / altitude range70 to 106 kPa (typical) ManualsLib

Storage / transport temperature–29 °C to 57 °C (–20 °F to 135 °F) (some sources) cnamedical.com 2ManualsLib 2

MountingCan be mounted on IV pole, headboard (for single channel), or other brackets; mounting bracket orientation can be changed ManualsLib 1

Power / Electrical / Battery

ParameterDetails

AC power input100–120 VAC, 50/60 Hz or 220–240 VAC, 50/60 Hz (auto-sensing) ManualsLib 2ManualsLib 2

Max power consumptionUp to ~ 40 W (max) (in some sources) dreveterinary.com

Fuses1.6 A, Type T (time delay), 250 V (external) dreveterinary.com 2ManualsLib 2

Power cordApprox. 2.9 m (9 ft) hospital?grade plug cable Ardus Medical 2ManualsLib 2

Battery type / recharge / runtimeFor single-channel model: 12 V sealed lead acid (2.0 Ah) battery in some sources (or equivalent) dreveterinary.com Fully charged new battery: ~ 5 hours of operation at 100 mL/hr dreveterinary.com 1 Battery recharge: 8 hours to reach ~80% charge dreveterinary.com 2ManualsLib 2 For battery in triple channels, runtime is shorter (often ~3 hours at 100 mL/hr for all channels) cnamedical.com 1

Battery charge indicator / “low battery” alarmsThe device includes battery charge level indication and alarms when battery is low. cnamedical.com 3ManualsLib 3ManualsLib 3

Infusion / Flow / Performance

Parameter / FeatureValue / Description

Flow rate (primary infusion)0.1 to 99.9 mL/hr in 0.1 mL/hr increments; 1 to 1200 mL/hr in 1 mL/hr increments cnamedical.com 4ManualsLib 4ManualsLib 4

Flow rate (secondary / piggyback infusion)0.1 to 99.9 mL/hr in 0.1 increments; 1 to 500 mL/hr in 1 mL/hr increments Ardus Medical 2ManualsLib 2

Volume to be Infused (VTBI)0.1 to 99.9 mL in 0.1 mL increments; 1 to 9999 mL in 1 mL increments Ardus Medical 3ManualsLib 3ManualsLib 3

Keep Vein Open (KVO) rate0.1 to 5 mL/hr in 0.1 increments (or programmed rate, whichever is less) cnamedical.com 3dreveterinary.com 3ManualsLib 3

Priming (prime) rate~ 500 mL/hr (to prime the tubing when not connected to patient) pi Veterinary Consultants 3cnamedical.com 3ManualsLib 3

AccuracyFor a 100 mL/hr rate over 1-hr period: ±5% or better over 72 hours; for very low rates (<1 mL/hr), accuracy within ±10% or over 0.5 mL, whichever is greater dreveterinary.com 2ManualsLib 2

Air bubble detection / alarmConfigurable air sensor settings (e.g. accumulation volumes of 25 µL, 50 µL, 100 µL, 150 µL) pi Veterinary Consultants 3ManualsLib 3ManualsLib 3

Downstream occlusion detectionConfigurable occlusion pressure thresholds (sensitivity) depending on flow rate ranges cnamedical.com 2ManualsLib 2

Auto-restart featureIf occlusion is relieved within about 1 minute, the pump can automatically resume (configurable option) cnamedical.com 2ManualsLib 2

Fluid viscosity / rangeWorks over a viscosity range of ~0.69 cP to 10.12 cP in some references ManualsLib

Container height influenceThe pump functions across varying heights of source containers (from –36 inches to 48 inches relative to the pump) pi Veterinary Consultants 3cnamedical.com 3ManualsLib 3

Flow check / resistance displaySome versions include a flow check graphic (representing in-line resistance downstream) dreveterinary.com 1

Limits & alarmsThe pump supports alarm thresholds and accumulation volumes (e.g. for air detection), volume accumulation thresholds, upstream/downstream occlusion alarms, door open, battery low, pump failure, communication timeout, etc. cnamedical.com 3ManualsLib 3ManualsLib 3

Features / Usability / Controls / Interfaces

  • Configurable PERSONALITY feature sets: The pump allows selection and storage of up to 8 custom “personality” profiles (sets of operating parameters) to match specific clinical environments or protocols. ManualsLib 2ManualsLib 2

  • Label library: The pump offers a built?in label library (predefined drug/solution names) and ability to define custom labels to display on screens and pump modules. ManualsLib 2pi Veterinary Consultants 2

  • Panel lockout / Auto lock: To prevent inadvertent tampering, some versions include a lockout of the keypad, and auto lock functionality. cnamedical.com 3ManualsLib 3ManualsLib 3

  • Automatic tube loading & misload detection: The pump is designed to assist with loading the administration set and detect misloaded tubing segments. ManualsLib 1

  • Delay start / programmed delayed infusion start: Optionally delay the start of an infusion per programming. ManualsLib 1

  • Communications / interfaces: ? • RS?232 communications port for data/configuration transfer pi Veterinary Consultants 3ManualsLib 3ManualsLib 3 ? • Remote nurse-call interface capabilities (alarm alerts to external systems) Ardus Medical 2ManualsLib 2 ? • Configuration transfer cable (Baxter product code 2M8155) to copy configuration between pumps ManualsLib 1

  • Diagnostics / self-tests: On power up, the pump runs self-diagnostic tests; the pump also supports diagnostic modes for service and maintenance. ManualsLib 1

  • Safety features & alarm hierarchy: The pump includes multiple alarm categories (alerts, alarms) for e.g. air in line, occlusion, door open, battery low, pump failure, communications timeout, etc. ManualsLib 2ManualsLib 2

  • Color-coded tubing guides (especially for multi-channel / triple-channel models) to assist users in distinguishing lines

Didn’t find what you were looking for? Place your own ad on the Bimedis platform

Place your advert on Bimedis and reach buyers worldwide.

SELL

Related searches