BAXTER COLLEAGUE CXE VOLUMETRIC INFUSION PUMP
AS SHOWN IN PICTURES THE SCREEN HAS A SMALL DENT BUT EVERYTHING ON THIS UNIT STILL WORKS PERFECTLY.
Below is a detailed (though not absolutely exhaustive) specification and feature breakdown for the Baxter COLLEAGUE CXE (model codes 2M91617 / 2M91637 etc.) volumetric infusion pump, compiled from available operator’s manuals and reference sources. If you want a specific variant (single?channel vs triple?channel, or regional edition), I can pull up those details too.
General / Product Identity
ItemDescription
Product familyBaxter COLLEAGUE CXE volumetric infusion pump ManualsLib 2ManualsLib 2
Model / product codes2M91617, 2M91637 (and variants like 2M91617A, 2M91637A) pi Veterinary Consultants 3ManualsLib 3ManualsLib 3
ChannelsAvailable as single?channel (COLLEAGUE CXE) and triple?channel (COLLEAGUE 3 CXE) versions medwrench.com 3ManualsLib 3ManualsLib 3
Intended useFor controlled delivery of fluids, medications, infusions (IV, intra-arterial, subcutaneous, etc.), including continuous or intermittent delivery pi Veterinary Consultants 2ManualsLib 2
Physical & Environmental Specifications
ParameterValue / Range
Dimensions (H × W × D)~ 10.0 in × 7.75 in × 7.75 in (? 254 × 197 × 197 mm) (excluding clamp knob or power cord) Ardus Medical 4dreveterinary.com 4ManualsLib 4
Weight~ 10.4 lb (~?4.7 kg) for the single channel version dreveterinary.com 2ManualsLib 2 Triple?channel version weight ~ 7.9 kg (? 17.5 lb) including mounting clamp ManualsLib 2ManualsLib 2
Operating temperature15 °C to 38 °C (59 °F to 100 °F) ManualsLib 2ManualsLib 2
Relative humidity (operating)20% to 95% non?condensing ManualsLib 1
Barometric pressure / altitude range70 to 106 kPa (typical) ManualsLib
Storage / transport temperature–29 °C to 57 °C (–20 °F to 135 °F) (some sources) cnamedical.com 2ManualsLib 2
MountingCan be mounted on IV pole, headboard (for single channel), or other brackets; mounting bracket orientation can be changed ManualsLib 1
Power / Electrical / Battery
ParameterDetails
AC power input100–120 VAC, 50/60 Hz or 220–240 VAC, 50/60 Hz (auto-sensing) ManualsLib 2ManualsLib 2
Max power consumptionUp to ~ 40 W (max) (in some sources) dreveterinary.com
Fuses1.6 A, Type T (time delay), 250 V (external) dreveterinary.com 2ManualsLib 2
Power cordApprox. 2.9 m (9 ft) hospital?grade plug cable Ardus Medical 2ManualsLib 2
Battery type / recharge / runtimeFor single-channel model: 12 V sealed lead acid (2.0 Ah) battery in some sources (or equivalent) dreveterinary.com Fully charged new battery: ~ 5 hours of operation at 100 mL/hr dreveterinary.com 1 Battery recharge: 8 hours to reach ~80% charge dreveterinary.com 2ManualsLib 2 For battery in triple channels, runtime is shorter (often ~3 hours at 100 mL/hr for all channels) cnamedical.com 1
Battery charge indicator / “low battery” alarmsThe device includes battery charge level indication and alarms when battery is low. cnamedical.com 3ManualsLib 3ManualsLib 3
Infusion / Flow / Performance
Parameter / FeatureValue / Description
Flow rate (primary infusion)0.1 to 99.9 mL/hr in 0.1 mL/hr increments; 1 to 1200 mL/hr in 1 mL/hr increments cnamedical.com 4ManualsLib 4ManualsLib 4
Flow rate (secondary / piggyback infusion)0.1 to 99.9 mL/hr in 0.1 increments; 1 to 500 mL/hr in 1 mL/hr increments Ardus Medical 2ManualsLib 2
Volume to be Infused (VTBI)0.1 to 99.9 mL in 0.1 mL increments; 1 to 9999 mL in 1 mL increments Ardus Medical 3ManualsLib 3ManualsLib 3
Keep Vein Open (KVO) rate0.1 to 5 mL/hr in 0.1 increments (or programmed rate, whichever is less) cnamedical.com 3dreveterinary.com 3ManualsLib 3
Priming (prime) rate~ 500 mL/hr (to prime the tubing when not connected to patient) pi Veterinary Consultants 3cnamedical.com 3ManualsLib 3
AccuracyFor a 100 mL/hr rate over 1-hr period: ±5% or better over 72 hours; for very low rates (<1 mL/hr), accuracy within ±10% or over 0.5 mL, whichever is greater dreveterinary.com 2ManualsLib 2
Air bubble detection / alarmConfigurable air sensor settings (e.g. accumulation volumes of 25 µL, 50 µL, 100 µL, 150 µL) pi Veterinary Consultants 3ManualsLib 3ManualsLib 3
Downstream occlusion detectionConfigurable occlusion pressure thresholds (sensitivity) depending on flow rate ranges cnamedical.com 2ManualsLib 2
Auto-restart featureIf occlusion is relieved within about 1 minute, the pump can automatically resume (configurable option) cnamedical.com 2ManualsLib 2
Fluid viscosity / rangeWorks over a viscosity range of ~0.69 cP to 10.12 cP in some references ManualsLib
Container height influenceThe pump functions across varying heights of source containers (from –36 inches to 48 inches relative to the pump) pi Veterinary Consultants 3cnamedical.com 3ManualsLib 3
Flow check / resistance displaySome versions include a flow check graphic (representing in-line resistance downstream) dreveterinary.com 1
Limits & alarmsThe pump supports alarm thresholds and accumulation volumes (e.g. for air detection), volume accumulation thresholds, upstream/downstream occlusion alarms, door open, battery low, pump failure, communication timeout, etc. cnamedical.com 3ManualsLib 3ManualsLib 3
Features / Usability / Controls / Interfaces
Configurable PERSONALITY feature sets: The pump allows selection and storage of up to 8 custom “personality” profiles (sets of operating parameters) to match specific clinical environments or protocols. ManualsLib 2ManualsLib 2
Label library: The pump offers a built?in label library (predefined drug/solution names) and ability to define custom labels to display on screens and pump modules. ManualsLib 2pi Veterinary Consultants 2
Panel lockout / Auto lock: To prevent inadvertent tampering, some versions include a lockout of the keypad, and auto lock functionality. cnamedical.com 3ManualsLib 3ManualsLib 3
Automatic tube loading & misload detection: The pump is designed to assist with loading the administration set and detect misloaded tubing segments. ManualsLib 1
Delay start / programmed delayed infusion start: Optionally delay the start of an infusion per programming. ManualsLib 1
Communications / interfaces: ? • RS?232 communications port for data/configuration transfer pi Veterinary Consultants 3ManualsLib 3ManualsLib 3 ? • Remote nurse-call interface capabilities (alarm alerts to external systems) Ardus Medical 2ManualsLib 2 ? • Configuration transfer cable (Baxter product code 2M8155) to copy configuration between pumps ManualsLib 1
Diagnostics / self-tests: On power up, the pump runs self-diagnostic tests; the pump also supports diagnostic modes for service and maintenance. ManualsLib 1
Safety features & alarm hierarchy: The pump includes multiple alarm categories (alerts, alarms) for e.g. air in line, occlusion, door open, battery low, pump failure, communications timeout, etc. ManualsLib 2ManualsLib 2
Color-coded tubing guides (especially for multi-channel / triple-channel models) to assist users in distinguishing lines