Product Details
| Model | Stellant D |
| Brand | MEDRAD |
| Category | Injectors CT |
| Posted | 19.02.2026 |
| Views | 254 |
Product Specifications
- Voltage, V ⓘ
- 100/240
- Frequency, Hz
- 50/60
- Minimum injection rate, ml/seс
- 0.1
- Maximum injection rate, ml/seс
- 10
- Volume of contrast agent syringe, ml
- 200
- Saline syringe volume, ml
- 200
Refurbished MEDRAD Stellant D
Condition:: Refurbished
Shipping from::
USA
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
Medrad Stellant Injectors Features:
Integral part of Bayer’s CT imaging solution, delivering efficiency and patient-centered care in CT imaging.
Scalable informatics-ready solution offering radiation dose management and Contrast Dose Management options.
Supports injector interfacing between the scanner, PACS, RIS, and speech recognition systems.
Workflow-centralized interface for efficient management of injection protocols in complex CT angiography and cardiac CT studies.
Capable of storing and recalling up to 250 protocols.
SPECIFICATIONS Medrad Stellant Specifications:
Injection Specifications:
Flow Rate: 0.1 to 10 mL/sec in 0.1 mL increments
Volume: 1 mL to syringe capacity in 1 mL increments
Programmable Pressure Limit: 325 psi, 2241 kPa
General Specifications:
Electrical Requirements: 100-240 VAC, 50/60 Hz, 300 Volts-AMPs
Syringe Heat Maintainer Range: 95 degrees F ± 9 degrees; 35 degrees C ± 5 degrees
Head Mounting Options: Overhead Counterpoise System or Floor Pedestal
Integral part of Bayer’s CT imaging solution, delivering efficiency and patient-centered care in CT imaging.
Scalable informatics-ready solution offering radiation dose management and Contrast Dose Management options.
Supports injector interfacing between the scanner, PACS, RIS, and speech recognition systems.
Workflow-centralized interface for efficient management of injection protocols in complex CT angiography and cardiac CT studies.
Capable of storing and recalling up to 250 protocols.
SPECIFICATIONS Medrad Stellant Specifications:
Injection Specifications:
Flow Rate: 0.1 to 10 mL/sec in 0.1 mL increments
Volume: 1 mL to syringe capacity in 1 mL increments
Programmable Pressure Limit: 325 psi, 2241 kPa
General Specifications:
Electrical Requirements: 100-240 VAC, 50/60 Hz, 300 Volts-AMPs
Syringe Heat Maintainer Range: 95 degrees F ± 9 degrees; 35 degrees C ± 5 degrees
Head Mounting Options: Overhead Counterpoise System or Floor Pedestal
Didn’t find what you were looking for? Place your own ad on the Bimedis platform
Place your advert on Bimedis and reach buyers worldwide.