Bimedis

Product Details

ModelG7112B 1260 Series
BrandAGILENT
CategoryHPLC Pumps
Posted16.02.2026
Views250

Used AGILENT G7112B 1260 Series


Condition:: Used
Shipping from:: USA

Safe deal

Bimedis secures your payment until you confirm the equipment is received.

Description

The Agilent 1260 Infinity II Binary Pump is suited for LC applications using conventional or superficially porous particle columns, as well as STM column technology. Gradient formation is based on a high-pressure mixing principle. Standard or low delay volumes can be easily configured by the user. The Agilent 1260 Infinity II Binary Pump offers reproducible gradients and high-performance, providing high-throughput and fast separations. The pump is suitable for routine applications, with UV or MS detection, where high speed and resolution with uncompromised data quality are required.

Specifications:

Physical Specifications;

Weight: 17.6 kg (38.8 lbs)
Dimensions (height × width × depth): 180 x 396 x 436 mm (7.1 x 15.6 x 17.2 inches)
Line voltage: 100 – 240 V~, ± 10 %
Line frequency: 50 or 60 Hz, ± 5 %
Power consumption: 90 VA, 74 W
Ambient operating temperature: 4–55 °C (39–131 °F)
Ambient non-operating temperature: -40 – 70 °C (-40 – 158 °F)
Humidity: < 95 % r.h. at 40 °C (104 °F)
Operating altitude: Up to 3000 m (9842 ft)
Non-operating altitude: Up to 4600 m (15091 ft)

Performance Specifications;

Hydraulic system: Two dual piston in series pumps with servo-controlled variable stroke drive, power transmission by gears and ball screws, floating pistons
Flow range: settable: 0.001 – 5 mL/min, recommended: 0.05 – 5.0 mL/min
Flow precision: ≤0.07 % RSD or < 0.02 min SD, whichever is greater
Flow accuracy: ± 1 % or 10 µL/min, whichever is greater
Pressure operating range: Up to 60 MPa (600 bar, 8702 psi) up to 5 mL/min
Pressure pulsation:
< 2 % amplitude (typically < 1.3 %), or
< 0.3 MPa (3 bar, 44 psi), whichever is greater
Low delay volume configuration: < 5 % amplitude (typically < 2 %)
Compressibility compensation: Pre-defined, based on mobile phase compressibility
Recommended pH range: 1.0 – 12.5
Gradient formation: High-pressure binary mixing
Delay volume:
Standard delay volume
Configuration: :600 – 900 µL, (includes 400 µL mixer)
Low delay volume configuration:120 µL
Composition range: Settable: 0 – 100 %, Recommended: 1 – 99 % or 5 µL/min per channel, whichever is greater
Composition precision: < 0.15 % RSD or < 0.04 min SD, whichever is greater
Composition accuracy: ± 0.35% absolute
Integrated degassing unit:
Number of channels: 2
Internal volume per channel: 0.45 mL
Communication:
Controller Area Network (CAN)
Local Area Network (LAN)
Extended Remote Interface (ERI)
Universal Serial Bus (USB)

Didn’t find what you were looking for? Place your own ad on the Bimedis platform