Used AGILENT G4220A 1290 Infinity
Condition:: Used
Shipping from::
USA
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
The Binary pump is designed for highest performance, GLP compliance and easy maintenance.
It includes the following features:
• Seal wash for continued high lifetime of pump seals for buffer applications.
• Solvent selection valve for method flexibility.
• Jet Weaver for optimum mixing performance with a minimum of delay volume.
• Automatic purge function for ease of use and unattended preparation of the system.
• Auto tuning of the delivery cycle for compensation of elasticity and solvent volume change effects (compressibility, thermal expansion, mixing contraction).
• Solvent selection for optimum flow and composition accuracy.
• Fast defill function for improved intake and delivery performance.
• Two pistons in series design for increased reliability.
• High resolution piston movement control for smooth and reliable motion.
Specifications:
Hydraulic system: Two dual pistons in series pumps with proprietary servo-controlled variable stroke design, power transmission by ball screws, smooth motion control of pistons for active damping.
Settable flow range: Setpoints 0.001—5 ml/min, in 0.001 ml/min increments.
Flow precision: ≤0.07 % RSD or 0.005 min SD, whatever is greater (0.2—5.0 ml/min).
Flow accuracy: ±1 % or 10 µl/min, whatever is greater.
Pressure operating range: Operating range up to 120 MPa (1200 bar), up to 2 ml/min, 80 MPa (800 bar) at 5 ml/min.
Pressure pulsation:
It includes the following features:
• Seal wash for continued high lifetime of pump seals for buffer applications.
• Solvent selection valve for method flexibility.
• Jet Weaver for optimum mixing performance with a minimum of delay volume.
• Automatic purge function for ease of use and unattended preparation of the system.
• Auto tuning of the delivery cycle for compensation of elasticity and solvent volume change effects (compressibility, thermal expansion, mixing contraction).
• Solvent selection for optimum flow and composition accuracy.
• Fast defill function for improved intake and delivery performance.
• Two pistons in series design for increased reliability.
• High resolution piston movement control for smooth and reliable motion.
Specifications:
Hydraulic system: Two dual pistons in series pumps with proprietary servo-controlled variable stroke design, power transmission by ball screws, smooth motion control of pistons for active damping.
Settable flow range: Setpoints 0.001—5 ml/min, in 0.001 ml/min increments.
Flow precision: ≤0.07 % RSD or 0.005 min SD, whatever is greater (0.2—5.0 ml/min).
Flow accuracy: ±1 % or 10 µl/min, whatever is greater.
Pressure operating range: Operating range up to 120 MPa (1200 bar), up to 2 ml/min, 80 MPa (800 bar) at 5 ml/min.
Pressure pulsation: