Product Details
| Model | XN-3000 |
| Brand | SYSMEX |
| Category | Hematology Analyzer |
| Posted | 31.01.2026 |
| Views | 1479 |
Product Specifications
- Type of analyzer
- closed
- Number of parameters
- 30
- Sample size, microlitre
- 88
- Throughput, samples per hour
- 200
- Analizator type
- Automatic
- Sample Types
- Whole blood
- Cycle time (reaction), s
- 18
Used - Good SYSMEX XN-3000
Condition:: Used - Good
Availability:: In stock
Shipping from::
USA
Description
The XN-3000 configuration includes two XN analysis modules and a high-quality, fully-integrated slide maker and stainer module, our SP-10 unit. This offers great productivity while taking up minimal space. The XN-3000 also has the excellent Extended information-processing unit (IPU) on board as standard that can intelligently route and control your sample and data workflow.
If you have a medium-sized lab with a fair smear rate, you will appreciate the detail in the XN-3000 setup. Because the two analysis modules process rack samples simultaneously, it can accommodate any sample without slowing down â the modules work together perfectly. And you donât lose any precious time, even with abnormal samples.
The XN-3000 has a single point of entry and a single point of exit. Reflex testing occurs within the same loop, and before samples pass the SP-10 module. Sample racks are then sent to the SP-10 module where the samples needing a smear are removed. Like extended measurements, smears are only initiated if they offer additional diagnostic value. The analysis profile is extended automatically to include smear-making and staining, but you may also order this up front, for instance with known special samples.
If you have a medium-sized lab with a fair smear rate, you will appreciate the detail in the XN-3000 setup. Because the two analysis modules process rack samples simultaneously, it can accommodate any sample without slowing down â the modules work together perfectly. And you donât lose any precious time, even with abnormal samples.
The XN-3000 has a single point of entry and a single point of exit. Reflex testing occurs within the same loop, and before samples pass the SP-10 module. Sample racks are then sent to the SP-10 module where the samples needing a smear are removed. Like extended measurements, smears are only initiated if they offer additional diagnostic value. The analysis profile is extended automatically to include smear-making and staining, but you may also order this up front, for instance with known special samples.