
Product Details
| Model | BC-5800 |
| Brand | MINDRAY |
| Category | Hematology Analyzer |
| Posted | 26.01.2026 |
| Views | 307 |
Product Specifications
- Overall dimensions, cm ⓘ
- 66,4 х 61,3 х 58,5
- Type of analyzer
- open
- Number of parameters
- 27
- Sample size, microlitre
- 40-140
- Throughput, samples per hour
- 90
- Analizator type
- Automatic
- Sample Types
- Venous blood, Capillary blood
- Cycle time (reaction), s
- 40
- Weight (kg)
- 76
Used MINDRAY BC-5800
Condition:: Used
Year:: 2015
Availability:: In stock
Shipping from::
Poland
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
BC-5800_SN_RW-53003381
Year of manufacture 03.2015. Power supply for analyser 100-240VAC, 300W. Compressor power supply 220/230VAC. Maintenance, removal of labels. All tests performed without reagents. Analyser mechanical/electrical/electronic side starts correctly. Password: admin/admin.
Test procedure:
1. CR1220 battery voltage check: faulty, replacement necessary, analyser loses date and time.
2. presence of reagents simulated.
3. expiry date of reagents changed.
4. analyser software version - Boot software: 1.3.5
5. Temp&Pres - temperatures and pressures in correct ranges.
6. Vol&Cur - voltages and currents in correct ranges. Laser diode current: 36.3 (range 20-50).
7. Self test: tests (Mechanical, Circuit, Valve) positive except: RBC Aperture Vol, Hgb Blank Voltage, Internal Barcode, Sample Feed, Sample Load, Sample Unload, Pierce Cylinder. Dobber - reagent missing. Errors are probably due to lack of reagents and lack of feeder.
8 Setup: date correction not performed, Print - user data was not present, Advanced (service password) - language change from Polish to English.
Kit composition:
1. analyser
2. compressor, year of manufacture 07.2015, SN: RWA57018626, 220/230VAC.
3. hand-held barcode scanner - NONE.
4. Complete hosing and cabling.
6. sample wands - NONE.
7. feeder (including internal barcode scanner) - NONE.
Year of manufacture 03.2015. Power supply for analyser 100-240VAC, 300W. Compressor power supply 220/230VAC. Maintenance, removal of labels. All tests performed without reagents. Analyser mechanical/electrical/electronic side starts correctly. Password: admin/admin.
Test procedure:
1. CR1220 battery voltage check: faulty, replacement necessary, analyser loses date and time.
2. presence of reagents simulated.
3. expiry date of reagents changed.
4. analyser software version - Boot software: 1.3.5
5. Temp&Pres - temperatures and pressures in correct ranges.
6. Vol&Cur - voltages and currents in correct ranges. Laser diode current: 36.3 (range 20-50).
7. Self test: tests (Mechanical, Circuit, Valve) positive except: RBC Aperture Vol, Hgb Blank Voltage, Internal Barcode, Sample Feed, Sample Load, Sample Unload, Pierce Cylinder. Dobber - reagent missing. Errors are probably due to lack of reagents and lack of feeder.
8 Setup: date correction not performed, Print - user data was not present, Advanced (service password) - language change from Polish to English.
Kit composition:
1. analyser
2. compressor, year of manufacture 07.2015, SN: RWA57018626, 220/230VAC.
3. hand-held barcode scanner - NONE.
4. Complete hosing and cabling.
6. sample wands - NONE.
7. feeder (including internal barcode scanner) - NONE.
Didn’t find what you were looking for? Place your own ad on the Bimedis platform
Place your advert on Bimedis and reach buyers worldwide.