We at International Diagnostic Equipment provide you with latest innovative Laboratory Equipment, clinical and analytical. We offer our equipment new, used, refurbished or re-certified. Along with the equipment we offer service, maintenance and repairs. We also offer reagents and consumables to keep your equipment and laboratory running productively and efficiently. We would love to speak with you to offer the best plan for your laboratory.
Description
We Have A Agilent Technologies 355 SCD Sulfur Chemiluminescence Detector
The 355 Sulfur Chemiluminescence Detector (355 SCD) is the world’s
most sensitive and selective chromatographic detector for sulfur containing compounds. The 355 SCD is based on patented technology, and it provides a linear and equimolar response to sulfur compounds without interference from most sample matrices. The exceptional performance of the 355 SCD has resulted in its widespread use and acceptance for the analysis of sulfur compounds in a wide range of applications. The new Dual Plasma Burner and Controller significantly enhance the performance of the 355 SCD, increase ease of use, and reduce maintenance.
Specifications
Sensitivity* Typical < 0.5 pg S/second (signal to noise 3.3:1)
Typical Selectivity g S/g C > 2 x 107
Linearity >104
Precision and Stabilityâ€
The 355 Sulfur Chemiluminescence Detector (355 SCD) is the world’s
most sensitive and selective chromatographic detector for sulfur containing compounds. The 355 SCD is based on patented technology, and it provides a linear and equimolar response to sulfur compounds without interference from most sample matrices. The exceptional performance of the 355 SCD has resulted in its widespread use and acceptance for the analysis of sulfur compounds in a wide range of applications. The new Dual Plasma Burner and Controller significantly enhance the performance of the 355 SCD, increase ease of use, and reduce maintenance.
Specifications
Sensitivity* Typical < 0.5 pg S/second (signal to noise 3.3:1)
Typical Selectivity g S/g C > 2 x 107
Linearity >104
Precision and Stabilityâ€