Product Details
| Model | HF-300 |
| Brand | OLYMPUS |
| Category | Electrosurgical Unit |
| Posted | 02.02.2026 |
| Views | 277 |
Used OLYMPUS HF-300
(plus shipping costs and VAT)
Price in seller currency:: 2 205 EUR
Seller:
trustpremiumapproved France
The Business Centre Medical (CAM)<br/>In a space of 2000 m2, with more than 7,000 articles are presented, stored, inspected, refurbished or reconditioned.<br/>Our offer covers all the needs of the profession, at all levels : equipment and medical devices, of course, but also technical equipment and furniture, for offices, clinics or hospitals.<br/>Why pay more ?<br/>The Business Centre Medical (CAM), is a company specialized in the sale of all types of equipment, medical, of which the common denominator is that they are for sale at discount prices. To meet this economic criteria, CAM responds to the needs for the two divisions :<br/>Department of new equipment<br/>Department equipment refurbished
Description
• Coagulation: 120 W
• Bipolar: 120 W
• Very good condition, used
HF DEVICE DELIVERED WITH ACCESSORIES (NEUTRAL PLATE, MONO AND BIPOLAR ELECTRODE,)
4.1 General Description Cutting with automatic HF voltage control (Auto Cut) It is equipped with open and closed loop control systems to control and regulate the relevant parameters for cutting quality so that each cut quality is guaranteed to be reproducible and consistent.
Soft coagulation:
Soft coagulation can be activated by a key or foot pedal. Forced coagulation: Forced coagulation is advantageous if effective hemostasis is to be achieved with relatively small surface area electrodes, such as TUR resection loops.
Spray coagulation:
The spray coagulation mode on the ICC is also suitable for argon gas coagulation. Adjustable power limitation in the different coagulation modes The surgically relevant coagulation qualities, i.e. the coagulation effects Soft Coag., Forced Coag., Spray Coag. and Bipolar Coag., are delimited by definition from each other and selectable by pressing a button. Nevertheless, the intensity of the individual effects can be changed by the power limitation.
Bipolar coagulation:
In this coagulation mode, the HF voltage is, similar to soft coagulation, automatically and constantly controlled, and its maximum value always remains below 200 Vp, so that the current density and thus the coagulation effect is, for the most part, independent of the effective contact surface between the coagulation electrode and the tissue, provided that the effective contact surface is not too large compared to the currently set power limitation.