Product Details
| Model | CP 150 |
| Brand | WELCH ALLYN |
| Category | Ecg machines |
| Posted | 02.02.2026 |
| Views | 368 |
Product Specifications
- Stationary or Portable ⓘ
- Portable
- ECG machine type
- 12-channel
New WELCH ALLYN CP 150
(plus shipping costs and VAT)
Price in seller currency:: 2 700 EUR
Seller:
trustpremiumapproved France
The Business Centre Medical (CAM)<br/>In a space of 2000 m2, with more than 7,000 articles are presented, stored, inspected, refurbished or reconditioned.<br/>Our offer covers all the needs of the profession, at all levels : equipment and medical devices, of course, but also technical equipment and furniture, for offices, clinics or hospitals.<br/>Why pay more ?<br/>The Business Centre Medical (CAM), is a company specialized in the sale of all types of equipment, medical, of which the common denominator is that they are for sale at discount prices. To meet this economic criteria, CAM responds to the needs for the two divisions :<br/>Department of new equipment<br/>Department equipment refurbished
Description
3x4-5.0 s at 50 mm/s 6x2-5.0 s at 25 mm/s 6x2-5.0 s at 50 mm/s 12x1-10.0 s at 25 mm/s • Report formats, internal printer, Average: 3x4+3R at 25 mm/s 3x4+3R at 50 mm/s 6x2+1R at 25 mm/s 6x2+1R at 50 mm/s No printing • ECG storage (in the test directory): At least 100 ECG tests • Patient storage: Up to 50 patients • Frequency range: 0.3 to 150 Hz • Digital sampling rate: > 1,000 samples/second/channel • Pacemaker detection: ANSI/AAMI EC11 • Power requirements: Universal AC power supply 110-240 V~, 50/60 Hz ~, 1.5 A maximum • Mains fuses: Time delay, rated 2.0 A 250 V, Littelfuse 0218002P or equivalent
• Rechargeable battery: 9 cells • Classification: 10.8 V 6.75 Ah (73 Wh) • Composition: Lithium-ion Charging time up to 90% capacity: 4 hours Full charge capacity: 25 ECG tests at 20 minutes per test
8 hours of continuous operation or 250 continuous ECGs
Filters • High performance baseline: 0.5 Hz • Muscle tremors: 35 Hz
• Mains interference: 50 Hz or 60 Hz • Standard connectivity: 1 USB client 4 USB hosts WiFi Ethernet • Connectivity with electronic medical records: DICOM tests sent via a wireless connection • Electrodes: Rigorously tested for conductivity, adhesion, and hypoallergenic qualities. Exceed all AAMI standards. • Power cable: Conforms to or exceeds type SJT. • Operating environmental conditions: Temperature +10°C to +40°C Relative humidity 15 to 95%, non-condensing (30 to 70% for printing) • Atmospheric pressure limits: 700 - 1060 hPa • Storage environmental conditions: Temperature -20°C to +50°C Relative humidity 15 to 95% non-condensing • Atmospheric pressure limits: 700 - 1060 hPa • Protection against electric shock: Type CF Class I and internal power supply • Operating mode: Continuous