Product Details
| Model | AED 10 |
| Brand | WELCH ALLYN |
| Category | Defibrillators |
| Posted | 19.02.2026 |
| Views | 228 |
Product Specifications
- Stationary or Portable ⓘ
- Portable
- Hand operated ⓘ
- Yes
- Automatic defibrillators
- Yes
Refurbished WELCH ALLYN AED 10
Condition:: Refurbished
Shipping from::
USA
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
Welch Allyn AED 10 Features:
Two-Button Operation: Simple design with only an on/off button and a shock button, making it easy to use even in stressful situations.
Text and Voice Instructions: Guides the user through the rescue process with both text and voice prompts, ensuring clarity and confidence.
Color-Coded Pads and Illustrations: Ensures proper placement of electrode pads, reducing the risk of error during usage.
Escalating Energy Levels: Offers escalating energy levels (150 J, 200 J, 300 J, 360 J) for shock delivery, with the energy protocol configurable to meet specific needs.
High-Performance Battery: Delivers up to five years of standby performance or over 90 discharges at 360 joules, ensuring reliability during emergencies.
Internal Memory: Stores event data including ECG waveforms, time/date stamps, shock delivery, and system actions, allowing for review and analysis.
Lightweight and Compact: Ideal for small spaces and portable use, ensuring accessibility in various settings.
Data Transfer Capability: Offers wireless data transfer from the device to a PC, facilitating record-keeping and analysis.
Welch Allyn AED 10 Specifications:
Dimensions:
Height: 2.75 (7 cm)
Width: 6.88 (17.5 cm)
Depth: 8.25 (21 cm)
Weight: 3.5 lbs (1.6 kg)
Data Management:
Event Documentation: Internal storage with a capacity of 1MB, capable of storing 250 4-sec ECG samples or 3000 time-stamped events.
Quick Report: Provides a treatment summary, event log, and test log for efficient review and analysis.
Communication: RS-232 via Infrared (IR) port for communication with a PC or printer.
Defibrillator:
Output: MRL Orbital Biphasic Truncated exponential waveform.
Energy Sequence: User-configurable sequence with multiple shock levels.
Charge Time: Ranges from 4 seconds to 15 seconds, depending on the energy level required.
Analysis Time: 4-16 seconds for analyzing the patient’s heart rhythm.
Audible and Visual Prompts: Provides 18 audible prompts and 20 text screen prompts for guidance during usage.
Controls: Four buttons including On/Off, Shock, and 2 software-configurable buttons.
Display:
Type: Backlit Monochrome LCD.
Size: 2.1 x 1.42 (54 x 36 mm) with a resolution of 160 x 100.
Low Battery Indicator: Battery icon gauge on the display with 10 capacity levels.
Backlight: LED for enhanced visibility in low-light conditions.
Battery:
Type: Non-rechargeable LiMnO2 12V, 2.6 Ah battery.
Capacity: Supports multiple discharges at different energy levels or up to 5 hours of ECG monitoring.
Shelf Life: 10 years at appropriate storage conditions.
Two-Button Operation: Simple design with only an on/off button and a shock button, making it easy to use even in stressful situations.
Text and Voice Instructions: Guides the user through the rescue process with both text and voice prompts, ensuring clarity and confidence.
Color-Coded Pads and Illustrations: Ensures proper placement of electrode pads, reducing the risk of error during usage.
Escalating Energy Levels: Offers escalating energy levels (150 J, 200 J, 300 J, 360 J) for shock delivery, with the energy protocol configurable to meet specific needs.
High-Performance Battery: Delivers up to five years of standby performance or over 90 discharges at 360 joules, ensuring reliability during emergencies.
Internal Memory: Stores event data including ECG waveforms, time/date stamps, shock delivery, and system actions, allowing for review and analysis.
Lightweight and Compact: Ideal for small spaces and portable use, ensuring accessibility in various settings.
Data Transfer Capability: Offers wireless data transfer from the device to a PC, facilitating record-keeping and analysis.
Welch Allyn AED 10 Specifications:
Dimensions:
Height: 2.75 (7 cm)
Width: 6.88 (17.5 cm)
Depth: 8.25 (21 cm)
Weight: 3.5 lbs (1.6 kg)
Data Management:
Event Documentation: Internal storage with a capacity of 1MB, capable of storing 250 4-sec ECG samples or 3000 time-stamped events.
Quick Report: Provides a treatment summary, event log, and test log for efficient review and analysis.
Communication: RS-232 via Infrared (IR) port for communication with a PC or printer.
Defibrillator:
Output: MRL Orbital Biphasic Truncated exponential waveform.
Energy Sequence: User-configurable sequence with multiple shock levels.
Charge Time: Ranges from 4 seconds to 15 seconds, depending on the energy level required.
Analysis Time: 4-16 seconds for analyzing the patient’s heart rhythm.
Audible and Visual Prompts: Provides 18 audible prompts and 20 text screen prompts for guidance during usage.
Controls: Four buttons including On/Off, Shock, and 2 software-configurable buttons.
Display:
Type: Backlit Monochrome LCD.
Size: 2.1 x 1.42 (54 x 36 mm) with a resolution of 160 x 100.
Low Battery Indicator: Battery icon gauge on the display with 10 capacity levels.
Backlight: LED for enhanced visibility in low-light conditions.
Battery:
Type: Non-rechargeable LiMnO2 12V, 2.6 Ah battery.
Capacity: Supports multiple discharges at different energy levels or up to 5 hours of ECG monitoring.
Shelf Life: 10 years at appropriate storage conditions.