ModelAquilion Prime 160
BrandTOSHIBA
CategoryCT Scanners
Posted03.02.2026
Views197

Product Specifications

X-ray tube voltage (kV)
80-135
Number of slices
160
Full 360° scan time (sec)
0,35
Minimum scan time (sec)
35
Scan fields of view (mm)
200
Reconstruction time, images/sec
60
Gantry aperture (mm)
780
X-ray tube current (mA)
10
X-ray tube capacity (MHU)
7.5
X-ray tube cooling rate (kHU/min)
1.39
Maximum patient weight (kg)
300

Product Video

Used - Good TOSHIBA Aquilion Prime 160


Condition:: Used - Good
Year:: 2016
Availability:: Expected
Shipping from:: New Zealand

Safe deal

Bimedis secures your payment until you confirm the equipment is received.

Description

Now available in June 2026.
SYSTEM REPORT: Canon (Toshiba) Aquilion Prime
About Wellington Regional Hospital
Wellington Hospital has 484 beds, and provides children's, maternity, surgical and medical services. This system is in the radiology department and is available for scanning 24 hours per day, 365 days per year. The radiology departments has two Cts installed side-by-side fulfilling all routine and emergency needs.
System condition
The system is in very good condition, the slicker is torn and would benefit from replacement, there are some scuffs (on the table covers especially) that would benefit from touch-up paint, but no cracks or other damage was visible on the system covers and accessories.
Image quality and overall performance
The QA test performed passed without issue, a complete history of the QA program that goes back to installation (see page 63). The system is used daily for both emergency and routine studies. The system is also fitted with radiotherapy planning table clamps and the room is fitted out with a LAP laser system (see page 24). Radiotherapy planning is not needed daily, but adds to the usefulness of this versatile system.
SYSTEM LOCATION Wellington Regional Hospital, Wellington, New Zealand
PROJECT NO.
PERFORMED BY Karl Wagener
DATE 20th December 2025
SYSTEM INFORMATION
Manufacturer and model Toshiba Aquilion Prime
System model no. TSX-303A
System serial no. BCB16Y2345
System YOM 2016
Number of slices 160
Air or water cooling? Air
GANTRY AND DETECTOR INFORMATION
Gantry YOM 2016
Gantry model no. CGGT-032A
Gantry serial no. 2AB16Y3024
Gantry count (rotations) 1434152
Detector model no. Purevision detector technology Detector
80 rows of 0.5 mm
Detector serial no. Not found, confirm at de-install.
Detector YOM Not found, confirm at de-install.
TUBE INFORMATION
Tube model name Varex
Tube model no. CXB-750G
Tube serial no. 49508-4P
Tube installation date 2025-02-20
Tube YOM Not found, confirm at de-install.
Tube count(s) (mAs, secs, count etc.)
SLICE TIME: 135698.5 SEC.
EXP. COUNT: 166469
Heat Exchanger Model (only Toshiba) N/A
Heat Exchanger running hours (only Toshiba) N/A
PATIENT TABLE INFORMATION
Table model no. CBTB-031A
Table serial no. 1AA16Y2863
Table YOM 2016
Head rest present? Yes.
Positioning pads incl.? Yes.
PDU INFORMATION (TRANSFORMER INFO)
PDU/transformer model no. CETF-006B
PDU/transformer serial no. 1AA16Y3030
PDU/transformer YOM 2016
COOLING CABINET INFORMATION (if applicable)
Cooling cabinet model no. N/A
Cooling cabinet serial no. N/A
Cooling cabinet YOM N/A
CONSOLE AND WORKSTATION(S) INFORMATION
Console model no. CKCN--017A
Console serial no. 2CA16Y2417
Console GOC (Only GE VCT) N/A
Console software version V8.2
Console software options SP0010E
Workstation (1) model no. N/A
Workstation (1) serial no. N/A
Workstation (1) SW version N/A
Workstation (1) SW options N/A
Workstation (2) model no. N/A
Workstation (2) serial no. N/A
Workstation (2) SW version N/A
Workstation (2) SW options N/A
ACCESSORIES, MANUAL HARD-COPIES AND SOFTWARE DISCS
Software and manuals (list) Yes, images below.
Any additional items/accessories? Yes, images below.
MAINTENANCE
Any major part replacements/service done? Heat exchanger PX71-08168-C (replaced March 2022). Image of job sheet below.
Is system logbook present? Yes, images below.
COMMENTS
Functional condition Fully functional, no issues reported.
Cosmetic condition Very good condition, see images below.
Slicker is torn and needs replacement.
No damaged or cracked covers were found.
Table covers were scuffed from normal wear and tear, would benefit from touch-up paint.
PHANTOMS
Model name Amount Model no. Serial no.
QA 1 Not found N/A
CALIBRATION 2 Not found N/A
QA TESTING
QA phantom test & analysis. Phantom QA scan, image of results on last page.