Product Specifications
- Number of slices ⓘ
- 64
- Stationary or Portable ⓘ
- Stationary
- Resolution, mm ⓘ
- 0.28
- Generator power (kW)
- 72
- Gantry aperture (mm) ⓘ
- 700
- Maximum patient weight (kg) ⓘ
- 305
- Minimum scan time (sec)
- 0.35
- Reconstruction time, images/sec
- 55
- Scan fields of view (mm)
- 2000
Used - Good GE Revolution EVO 64
Condition:: Used - Good
Year:: 2018
Shipping from::
USA
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
GE CT Revolution EVO 64-Slice
YOM 2018
T YOM 2025
Modality: CT
Manufacturer: GE
Model: REVOLUTION EVO
Installation Date: May 2018
System functional: Yes
Is the system used only in human environment? Yes – Has been used ONLY on Humans
Serviced by: Original manufacturer
Number of slices: 64
Installation date of the current X-Ray Tube: Apr 2025
Number of mAs or scan/seconds on the current X- Ray Tube: New tube was installed on May 6th 2025
Number of total rotations on the system: New tube was installed on May 6th 2025
Site activity (number of patient/year): 12000
Tube type in MHU: 5 and above
Was the system upgraded? No
If yes, provide upgrade installation date and updated configuration:
Generator Size: 48
Software Level/version: 16HW14.9
Application packages (Optional Software):
Does it have iterative reconstruction / dose reduction software? Yes
Table type: Short
Will the workstation be returned with the system? No
YOM 2018
T YOM 2025
Modality: CT
Manufacturer: GE
Model: REVOLUTION EVO
Installation Date: May 2018
System functional: Yes
Is the system used only in human environment? Yes – Has been used ONLY on Humans
Serviced by: Original manufacturer
Number of slices: 64
Installation date of the current X-Ray Tube: Apr 2025
Number of mAs or scan/seconds on the current X- Ray Tube: New tube was installed on May 6th 2025
Number of total rotations on the system: New tube was installed on May 6th 2025
Site activity (number of patient/year): 12000
Tube type in MHU: 5 and above
Was the system upgraded? No
If yes, provide upgrade installation date and updated configuration:
Generator Size: 48
Software Level/version: 16HW14.9
Application packages (Optional Software):
Does it have iterative reconstruction / dose reduction software? Yes
Table type: Short
Will the workstation be returned with the system? No
Didn’t find what you were looking for? Place your own ad on the Bimedis platform
Place your advert on Bimedis and reach buyers worldwide.