Product Details
| Model | ANATOM A200 |
| Brand | ANKE |
| Category | CT Scanners |
| Posted | 06.02.2026 |
| Views | 538 |
Product Specifications
- Number of slices ⓘ
- 32
New ANKE ANATOM A200
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
- Less Transmission Loss
The new OptiWave™ Detector leverages integrated circuit systems to ensure lossless transmission of imaging data. This optimized data transfer process enhances the speed and accuracy of image acquisition.
- Longer Detector Lifetime
CT detector lifespan is affected by signal loss from radiation and usage. The OptiWave™ Detector, with its superior design, experiences under 8% signal loss from radiation after a decade, prolonging its life and maximizing user investment.
- Less Power Consumption
Lower power consumption not only reduces operational costs but also contributes to a more sustainable, eco-friendly approach to healthcare technology. It aligns with the demand for energy-efficient medical devices.
- Strong Anti-interference Capability
The OptiWave™ Detector has a compact design with integrated digital module and ADC, simplifying connections and enhancing resistance to interference by removing the need for high-density analog signal cables.
- Low-dose Lung Cancer Screening Solution
• Preservation of fine bronchi, enabling the accurate detection of subtle nodules.
• Enhanced clarity of lung parenchyma, with sharp pleural edges.
• Minimizing mediastinal noise enhances the visibility of lymph nodes.
- Advanced Soft Tissue Imaging Solution for Abdominal Scans
• Enhances visibility of soft tissue masses and lymph nodes.
• Preserves renal and vascular details, reduces noise in the pelvic area.
• Facilitating the accurate detection of small lesions and abnormalities.
1)Adose Technology
• Adjusts tube current for patient anatomy.
• Delivers lowest required radiation dose.
• Optimizes current for clearer diagnostic images.
• Reduces radiation exposure to enhance safety.
2)Dose Monitoring
• Real-time tracking of radiation doses.
• Alerts for high dose thresholds.
• Facilitates patient safety assessments.
3)Pediatric Protocols
• Customized protocols for young patients.
• Minimized radiation exposure during scans.
• Ensures high-quality imaging results.
4)70 kVp Technology
• Reduce the amount of contrast agent required
, minimize renal stress.
• Reduce radiation doses by up to 85% compared to traditional 120 kVp.