Product Details

ModelCobas Integra 400 plus
BrandROCHE
CategoryBiochemical Analyzers
Posted26.01.2026
Views405

Product Specifications

Type of analyzer
open
Sample size, microlitre
2-10
Throughput, samples per hour
400
Analizator type
Automatic
Cycle time (reaction), s
10.6
Wavelength ranges, nm
340-800
Sample Types
Plasma, Serum, Urine, CSF, whole blood
ISE
Yes
Weight (kg)
230
Overall dimensions, cm
135х66х75

Used ROCHE Cobas Integra 400 plus


Condition:: Used
Availability:: In stock
Shipping from:: Poland

Safe deal

Bimedis secures your payment until you confirm the equipment is received.

Description

Many deficiencies of the analyzer have been corrected: Needle 2 pcs. / Black, aluminum lamp cover / Rotor (28110328001) / Rotor cover (04914163001) / Waste water container (28075395001) / Dosing syringes 2 pcs. / Upper, transparent cover of the washing block (28098158001) / External water container (28108277001) / Internal water container (28119449001) / ISE rack (28155917001) / Upper drawer for cuvettes (28176272001) / Upper cover of the cuvette feeder-vibrator (28185239001) / Connector-water connection, male and female (10045070) CPC w/check valve tubing wash 1 and (10045619) Quick connector 1/8” PP Shut). Its Abs Photometer” (working) was taken to another analyzer (with SN: 389471). In this analyzer, an Abs Photometer” sent by the analyzer supplier with SN: 389471 (under warranty for the damaged block) was installed. The Abs Photometer” block was tested and photos of the test results were taken.
In the PC (HP, RP5810, Serial No.: CZC9319Y9W) one disk (with data) is missing. A clone of such a disk does not start correctly with the original disk with software. Only after making clones of both disks (clone designation: 2009.03.09 10:18 / 2009.03.09 10:23) the software started correctly. Earlier, clones were made for the HP PC, RP5800, but after starting, a message about a conflict with the computers serial number appeared. This one original HD was left in the service for other uses. Maintenance of the optocoupler at needle B. Change of power supply (change of connector connections) to 230AC. Gluing the left housing of the analyzer. Maintenance of the analyzer. The analyzer reports readiness for operation. Accessories included - see photo. It has 6 sample crayons and 8 reagent crayons (there was only 1 pc., 7 pcs. were refilled). 3 different ISE elements (Over flow collector / locking bold / ISE Tower) were refilled.