Product Details
| Model | JCA-BM6010 |
| Brand | JEOL |
| Category | Biochemical Analyzers |
| Posted | 26.01.2026 |
| Views | 822 |
Product Specifications
- Analizator type
- Automatic
- Type of analyzer
- closed
Used JEOL JCA-BM6010
Condition:: Used
Availability:: In stock
Shipping from::
Poland
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
Overall performance: 1200 tests / h
Photometric determinations: 800 tests / h. ISE determinations (Na, K, Cl): 600 tests / h
Possibility to add cit samples during analyzes (separate port)
Optical system with 14 wavelengths: 340-884nm (340,410,451,478,505,545,571,596,658,694,751,805,845,884)
Innovative reaction disk thermostatic system to minimize optical interference
Small sample volume: 1-25μL / 84 sample positions with integrated barcode reader
Reaction volume from 80μL
Cooled reagent deck for 90 containers: 2 rotors with integrated barcode reader
Reagent sampling system consisting of 2 probes / possibility of using 3-reagent applications
Two separate stirrers for optimal homogenization of the reaction mixture
Sample probe equipped with a liquid level sensor and a clot sensor
Cooled control and calibrator rotor in 61 positions
Automatic dilutions and repeats
Reaction rotor for 231 reusable special plastic cuvettes
Advanced cuvette cleaning system to prevent contamination and minimize carryover
Water consumption: 20 L / h (water treatment plant)
Automatic start-up and shutdown according to the programmed weekly schedule
Dimensions / Weight: 122 cm (width) x 85 cm (depth) x 110.8 cm (height) / approx. 450 kg
Possibility to connect to the LIS laboratory network (two-way communication)
Items are sold as-is with no returns or refunds available unless explicitly stated.
Photometric determinations: 800 tests / h. ISE determinations (Na, K, Cl): 600 tests / h
Possibility to add cit samples during analyzes (separate port)
Optical system with 14 wavelengths: 340-884nm (340,410,451,478,505,545,571,596,658,694,751,805,845,884)
Innovative reaction disk thermostatic system to minimize optical interference
Small sample volume: 1-25μL / 84 sample positions with integrated barcode reader
Reaction volume from 80μL
Cooled reagent deck for 90 containers: 2 rotors with integrated barcode reader
Reagent sampling system consisting of 2 probes / possibility of using 3-reagent applications
Two separate stirrers for optimal homogenization of the reaction mixture
Sample probe equipped with a liquid level sensor and a clot sensor
Cooled control and calibrator rotor in 61 positions
Automatic dilutions and repeats
Reaction rotor for 231 reusable special plastic cuvettes
Advanced cuvette cleaning system to prevent contamination and minimize carryover
Water consumption: 20 L / h (water treatment plant)
Automatic start-up and shutdown according to the programmed weekly schedule
Dimensions / Weight: 122 cm (width) x 85 cm (depth) x 110.8 cm (height) / approx. 450 kg
Possibility to connect to the LIS laboratory network (two-way communication)
Items are sold as-is with no returns or refunds available unless explicitly stated.
Didn’t find what you were looking for? Place your own ad on the Bimedis platform
Place your advert on Bimedis and reach buyers worldwide.