Product Details
| Model | ILab 300 Plus |
| Brand | INSTRUMENTATION LABORATORY |
| Category | Biochemical Analyzers |
| Posted | 26.01.2026 |
| Views | 1026 |
Product Specifications
- Analizator type
- Automatic
- Type of analyzer
- closed
Used INSTRUMENTATION LABORATORY ILab 300 Plus
Condition:: Used
Availability:: In stock
Shipping from::
Poland
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
Used device, computer and printer included, AS IS.
Technical Specifications
Tests on board Up to 35 + 3 ISE
Test Menu Open System, over 150 Photometric + ISE
Throughput Up to 180 photometric tests/hour + up to 160 ISE tests/hour
Measuring Methods End Point, Fixed Time, Kinetic
Sample Loading Rack : 64 routine (continuous loading), + 14 STAT positions, + 14 Cal&QC positions
Sample containers Cup, micro cup, Primary tubes (diam. 10 -16, height 50 - 100 mm)
Sample volume From 3 to 99 µL (step 1 µL)
Reagent dispensing system Direct System, 1 to 3 reagents/test
Reagents on Board 35 (+ 1 ISE); 20 refrigerated
Reagent Volume From 25 to 400 µL (step 1 µL)
Reaction cuvette 60 semi disposable optical cuvettes, system laundry
Reaction cuvette volume min. 290 µL max. 600 µL
Deionized water and diluent usage About 4 mL/test
Wavelengths 8, range 340 to 620 nm.
Host Interface Bi-directional RS-232; host query or batch mode
Installation Requirements
Power 100-230 VAC, 47-63 Hz, 300 W
Temperature / Relative Humidity 18-30 °C , 20-85 % RH non condensing
Dimensions and weight 100 cm width, 65 cm depth, 42 cm height, 65 Kg
PC / Printer Pentium PC / 80 column impact printer, Laser printer
Options
Sample Bar-code reader, ISE module (Na, K, Cl)
Items are sold as-is with no returns or refunds available unless explicitly stated.
Technical Specifications
Tests on board Up to 35 + 3 ISE
Test Menu Open System, over 150 Photometric + ISE
Throughput Up to 180 photometric tests/hour + up to 160 ISE tests/hour
Measuring Methods End Point, Fixed Time, Kinetic
Sample Loading Rack : 64 routine (continuous loading), + 14 STAT positions, + 14 Cal&QC positions
Sample containers Cup, micro cup, Primary tubes (diam. 10 -16, height 50 - 100 mm)
Sample volume From 3 to 99 µL (step 1 µL)
Reagent dispensing system Direct System, 1 to 3 reagents/test
Reagents on Board 35 (+ 1 ISE); 20 refrigerated
Reagent Volume From 25 to 400 µL (step 1 µL)
Reaction cuvette 60 semi disposable optical cuvettes, system laundry
Reaction cuvette volume min. 290 µL max. 600 µL
Deionized water and diluent usage About 4 mL/test
Wavelengths 8, range 340 to 620 nm.
Host Interface Bi-directional RS-232; host query or batch mode
Installation Requirements
Power 100-230 VAC, 47-63 Hz, 300 W
Temperature / Relative Humidity 18-30 °C , 20-85 % RH non condensing
Dimensions and weight 100 cm width, 65 cm depth, 42 cm height, 65 Kg
PC / Printer Pentium PC / 80 column impact printer, Laser printer
Options
Sample Bar-code reader, ISE module (Na, K, Cl)
Items are sold as-is with no returns or refunds available unless explicitly stated.