New HACH TL2350
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
Unused Hach TL2350 Tungsten Lamp Turbidimeter, EPA, 0 - 10000 NTU
Description:
Hach laboratory opacimeter model TL 2350 EPA
Technical specifications
Dimensions (H x W x D): 153 mm x 395 mm x 305 mm
Response: Signal averaging 6.8 seconds;
Signal averaging a time: 14 seconds (if the calculation of the average 10 measurements may be used)
Display: color touch screen display, 17.8 mm
Operating conditions: 0 - 40 ° C
Data acquisition: 2.000 Total protocols, including results log, audit log and calibration
Units: NTU, EBC, E (absorbance), T% (% transmittance) and mg / L
Accuracy: Absorbance: ± 0.01 E 0 to 0.5 E at 455 nm ± 2% E 0.5 to 1 E at 455 nm
Transmission: 2% T 10-100% T at 455 nm
Ratio measurement a: ± 2% of reading plus 0.01 NTU 0-1000 NTU ± 5% of reading 1000-4000 NTU ± 10%
of reading 4000-10000 NTU
Ratio measurement of: ± 2% of reading plus 0.01 NTU 0-40 NTU
Weight: 3.0 kg
Communication: USB
Cuvette Compatibility: test tubes 95 x 25 mm, borosilicate glass with rubberized SchraubkappenHinweis: When using a cuvette adapter smaller sample cells (less than 25 mm) can be used.
Storage conditions: -20 - 60 ° C
Light source: tungsten lamp
Air Conditioner: Dry nitrogen or instrument air (ANSI MC 11.1, 1975) 0.05 L / s at 69 kPa; Max. 138 kPa, hose connection for 1/8 "hose
Measuring range: NTU (ratio measurement a): 0-10000 auto-dec.
NTU (ratio measurement of): 0 - 40
EBC (ratio measurement a): 0-2450 auto-dec.
EBC (ratio measurement of): 0 to 9.8
Absorbance (. Auto range): from 0 to 1.0
Transmission (%): 1.0 to 100
(Mg / L): 1-100
Measurement Method: ephelometrisch
Measuring modes: single measurement, continuous measurement mode "Rapidly Settling Turbidity" (for measuring fast absetzender samples), signal averaging switched on / off, ratio measurement ON / OFF
Standard: Meets EPA Method 180.1
Sample requirements: 25 mm sample cell: min. 20 mL, 0 - 70 ° C
Interface: 2 USB A ports for USB flash drive, external printer, keyboard and barcode scanner
Power (Amp): 3,4 A
Power supply (Hz): 50/60 Hz
Power supply (V): 100 - 240 V AC
Stabilisation: a ratio measurement: 30 minutes after start
Ratio measurement of: 60 minutes after start
Repeatability: ± 1% of reading or 0.01 NTU, whichever is greater (under reference conditions)
Certification: CE, KC, RCM