Bimedis

Product Details

ModelTrilogy 100
BrandPHILIPS
CategoryAnesthesia ventilators
Posted12.02.2026
Views302

Product Specifications

Minimum breathing capacity, ml
50
Maximum breathing capacity, ml
2000
Maximum respiratory rate, times/min.
60
Minimum oxygen concentration, %
21
Max Oxygen concentration,%
100

Refurbished PHILIPS Trilogy 100


Condition:: Refurbished
Warranty (month):: 6
Availability:: In stock
Shipping from:: USA

1 999

Safe deal

Bimedis secures your payment until you confirm the equipment is received.

Description

PRICE INCUDES DELIVERY FEES. YOUR CONTRY'S DUTIES ARE ADDITIONAL.

Simple Ventilation. Sophisticated Technology. Trilogy makes invasive and noninvasive home ventilation less complicated with a simplified user interface and Respironics' proven BiPAP technology for greater versatility. Its lightweight design and internal and detachable batteries make portability easier for patients on the go. Simplicity Light, versatile, and easy to use, Trilogy100 offers clinicians and patients one of life's greatest qualities - simplicity. Whether at home or in alternative care sites, the Trilogy100 portable volume and pressure support ventilator with BiPAP technology is made for adult and pediatric use. Offers Two Circuit Options Interchangeable active and passive exhalation porting blocks give clinicians the flexibility to choose the best available circuit and interface for patients. Its internal PEEP, combined with a single limb circuit, creates an uncomplicated application. Portability Trilogy100 has been designed with portability in mind. • Weighs 5 kg (11 lb.) • Includes 3-hour internal and 3-hour detachable batteries • Ability to connect to an external lead acid battery DirectView Ventilation Management Software Trilogy100 provides ventilation data and prescription management through the use of an SD memory card. Environmental Specifications Temperature: 5°C – 40°C Relative humidity: 15% – 95% Atmospheric pressure: 110 kPa to 60 kPa Physical Specifications Weight: 11 lbs, 5 kgs Size: 6.6L x 11.2W x 9.3H (16.68 cm L x 28.45 cm W x 23.52 cm H) Controls Circuit types: Active with PAP, passive Ventilation types: Volume control, pressure control, bilevel Volume modes: AC, SIMV (w/PS), CV Pressure modes: CPAP, S, S/T, T, PC-SIMV (w/PS) IPAP: 4 – 50 cm H20 EPAP: 0 – 25 cm H20 for active circuits; 4 – 25 cm H20 for passive circuits CPAP: 4 – 20 cm H20 for passive circuits PEEP: 0 – 25 cm H20 for active circuits; 4 – 25 cm H20 for passive circuits Pressure support differential: 0 – 30 cm H20 Measured Patient Parameters Tidal volume: 50 – 2000 ml Breath rate: 0 – 60 for AC mode, 1 – 60 for all other modes Inspiratory time: 0.3 – 5.0 secs Rise time: 1 – 6 Ramp start pressure: 0 – 25 cm H20 for active circuits; 4 – 25 cm H20 for passive circuits; 4 – 19 cm H20 in CPAP mode Ramp length: Off, 5 – 45 minutes Flex: Off, 1 – 3 Flow trigger sensitivity: 1 – 9 l/min Flow cycle: 10% – 90% Apnea rate: 4 – 60 BPM Tidal volume: 0 – 2000 ml Minute ventilation: 0 – 99 l/min Leak rate: 0 – 200 l/min Respiratory rate: 0 – 80 BPM Peak inspiratory flow: 0 – 200 l/min Peak inspiratory pressure: 0 – 99 cm H20 Mean airway pressure: 0 – 99 cm H20 Percentage patient triggered breaths: 0 – 100% I:E ratio: 9.9:1 to 1:9.9 Alarms Circuit disconnect: Off, 10 – 60 secs Apnea: Off, 10 – 60 secs High tidal volume: Off, 50 – 2000 ml Low tidal volume: Off, 50 – 2000 ml High minute ventilation: Off, .1 – 99 l/min Low minute ventilation: Off, .1 – 99 l/min High respiratory rate: Off, 4 – 80 BPM Low respiratory rate: Off, 4 – 80 BPM

Didn’t find what you were looking for? Place your own ad on the Bimedis platform

Place your advert on Bimedis and reach buyers worldwide.

SELL

Related searches