Bimedis

Product Details

ModelRespironics Trilogy 200
BrandPHILIPS
CategoryAnesthesia ventilators
Posted12.02.2026
Views304

Product Specifications

ALV machine type
Portable
Children’s ALV machines
Yes
High-frequency ALV machines
Yes
Mobile ALV machines
Yes

Refurbished PHILIPS Respironics Trilogy 200


Condition:: Refurbished
Warranty (month):: 3
Availability:: In stock
Shipping from:: USA

2 995

Safe deal

Bimedis secures your payment until you confirm the equipment is received.

Description

PRICE INCUDES DELIVERY FEES. YOUR CONTRY'S DUTIES ARE ADDITIONAL.

For Every Breath He Takes Using a new single limb circuit and proximal flow sensor, Trilogy200 offers improved triggering and leak compensation that allows for the more sensitive delivery of therapy. This added sensitivity decreases work of breathing, resulting in greater comfort, better ventilation, and improved patient/ventilator synchrony. Sensitive To Your Patient's Needs Trilogy200's advanced flow triggering is ideal for patients who require enhanced inspiratory triggering and leak compensation. Offers Three Circuit Options Trilogy200's new universal porting block gives you the flexibility to choose from three different circuit configurations and provide the best available option for the patient. Portability Trilogy200 has been designed with portability in mind. • Weighs 5 kg (11 lb.) • Includes 3-hour internal and 3-hour detachable batteries • Ability to connect to an external lead acid battery DirectView Ventilation Management Software Trilogy200 provides ventilation data and prescription management through the use of an SD memory card. Environmental Specifications Temperature: 5°C – 40°C Relative humidity: 15% – 95% Atmospheric pressure: 110 kPa to 60 kPa Physical Specifications Weight: 11 lbs, 5 kgs Size: 6.6 x 11.2 x 9.5, 16.68 x 28.45 x 23.52cm Controls Circuit types: Active with PAP, passive, active with flow Ventilation types: Volume control, pressure control, bilevel Volume modes: AC, SIMV (w/PS), CV Pressure modes: CPAP, S, S/T, T, PC-SIMV (w/PS) IPAP: 4 – 50 cm H20 EPAP: 0 – 25 cm H20 for active circuits; 4 – 25 cm H20 for passive circuits CPAP: 4 – 20 cm H20 for passive circuits PEEP: 0 – 25 cm H20 for active circuits; 4 – 25 cm H20 for passive circuits Pressure support differential: 0 – 30 cm H20 Control Accuracy Tidal volume: 50 – 2000 ml Breath rate: 0 – 60 for AC mode, 1 – 60 for all other modes Inspiratory time: 0.3 – 5.0 secs Rise time: 1 – 6 (The range of values corresponds to tenths of a second. For example, a setting of 4 indicates a rise time of 0.4 seconds.) Ramp start pressure: 0 – 25 cm H20 for active circuits; 4 – 25 cm H20 for passive circuits; 4 – 19 cm H20 in CPAP mode Ramp length: Off, 5 – 45 minutes Flex: Off, 1 – 3 Flow trigger sensitivity: 1 – 9 l/min Flow cycle: 10% – 90% Apnea rate: 4 – 60 BPM Measured Patient Parameters Tidal volume: 0 – 2000 ml Minute ventilation: 0 – 99 l/min Leak rate: 0 – 200 l/min Respiratory rate: 0 – 80 BPM Peak inspiratory flow: 0 – 200 l/min Peak inspiratory pressure: 0 – 99 cm H20 Mean airway pressure: 0 – 99 cm H20 Percentage patient triggered breaths: 0 – 100% I:E ratio: 9.9–1:1–9.9 Alarms Circuit disconnect: Off, 5 – 60 secs Apnea: Off, 10 – 60 secs High tidal volume: Off, 50 – 2000 ml Low tidal volume: Off, 40 – 2000 ml High minute ventilation: Off, 0.1 – 99 l/min Low minute ventilation: Off, 0.1 – 99 l/min High respiratory rate: Off, 4 – 80 BPM Low respiratory rate: Off, 4 – 80 BPM

Didn’t find what you were looking for? Place your own ad on the Bimedis platform

Place your advert on Bimedis and reach buyers worldwide.

SELL

Related searches