Product Details
| Model | Babylog 8000 plus |
| Brand | DRAGER |
| Category | Anesthesia ventilators |
| Posted | 30.12.2025 |
| Views | 1122 |
Product Specifications
- DIN working pressure, bar
- 80
- Inspiratory flow, L/min ⓘ
- 30
- Maximum respiratory rate, times/min.
- 200
- Minimum oxygen concentration, % ⓘ
- 21
Pre-Owned - Excellent DRAGER Babylog 8000 plus
Condition:: Pre-Owned - Excellent
Availability:: In stock
Shipping from::
USA
1 800
Description
Dräger Babylog 8000 Plus
The Drager Babylog 8000 plus offers Non-invasive respiratory support for Neonatal patients, including premature babies, newborns, and infants with a weight up to 44 lbs (20 kg). The Babylog was designed for harmonious ventilation, a platform that can adapt to the necessary need, from spontaneous breathing to changes in lung conditions. The Drager Babylog 8000 Plus is a high-frequency ventilation system that can provide CPAAP and IMV modes. The system can monitor inspiratory oxygen concentration, airway pressure, flow, tidal volume, and breathing rate. The patient's data can be transferred from the ventilator to either a patient monitor or a central monitoring station.
It can be used on Neonatal and Pediatric patients under the weight of 44 lbs or 20kg
Allows for optimal levels of spontaneous breathing
The Volume Guarantee (VG) features combine the advantage of pressure and volume-controlled ventilation
The integrated airway monitoring system can display waveforms of pressure and flow
DIMENSIONS
Height: 12.5 In (31.8 cm)
Width: 8.4 In (21.5 cm)
Depth: 15.2 In (38.5 cm)
Weight: 32 lbs
CONTROLS
Control principle Continuous flow, pressure-limited,time-cycled
Conventional ventilation IMV/IPPV, CPAP
Triggered ventilation IMV, SIPPV, PSV1), Leak adapted
Trigger Flow/volume trigger, Leak adapted
Trigger delay approx. 30 ms
High-Frequency Ventilation 1) 3) CPAP+HFV, IMV+HFV
Frequency 5 to 20 Hz
Volume Guarantee Ventilation) SIMV+VG, SIPPV+VG, PSV+VG
Oxygen mixer loss (bleed flow) 0 (zero) L/min
SETTINGS
Inspiratory Oxygen concentration 21 -100 vol. % oxygen
Peak inspiratory pressure 10 to 80 mbar
PEEP/CPAP 0 to 25 mbar
Maximal frequency 200 bpm2)
Inspiratory time 0.1 to 2 seconds
Expiratory time 0.2 to 30 seconds
Inspiratory flow 1 to 30 L/min
Base flow (VIVE) 1 to 30 L/min
MONITORING
Flow Monitoring at the Y-piece, integrated
Volume Monitoring at the Y-piece, integrated
Lung function monitoring Compliance, resistance C20/C, time constant
FiO2 Monitoring integrated
Real-time curves Flow and pressure, integrated
Inspiratory Oxygen concentration 21 -100 vol. % oxygen
Peak Pressure to 99 mbar
Mean Airway Pressure to 99 mbar
Graphic trends 6 parameters, integrated
Logbook record of last 100 alarms.
We can ship to NATION & WORLDWIDE.
We have more units in stock!
The pictures of the equipment are for reference only. Used medical equipment is constantly being renewed.
ATTENTION: Shipping costs only for Packing & Local Move in Miami to the shipping company. Not including any transportation. Please contact us if you need to know the shipping price. We will be glad to provide you with the best service.
Can Pick UP our equipment from our warehouse.
Good cosmetic condition; no signs of damage or abuse.
For FDA regulations, please, don´t hesitate to contact us.
DISCLAIMER:
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. The item is subject to FDA regulation; I will verify your status as an authorized purchaser of this item before shipping the item.
The Drager Babylog 8000 plus offers Non-invasive respiratory support for Neonatal patients, including premature babies, newborns, and infants with a weight up to 44 lbs (20 kg). The Babylog was designed for harmonious ventilation, a platform that can adapt to the necessary need, from spontaneous breathing to changes in lung conditions. The Drager Babylog 8000 Plus is a high-frequency ventilation system that can provide CPAAP and IMV modes. The system can monitor inspiratory oxygen concentration, airway pressure, flow, tidal volume, and breathing rate. The patient's data can be transferred from the ventilator to either a patient monitor or a central monitoring station.
It can be used on Neonatal and Pediatric patients under the weight of 44 lbs or 20kg
Allows for optimal levels of spontaneous breathing
The Volume Guarantee (VG) features combine the advantage of pressure and volume-controlled ventilation
The integrated airway monitoring system can display waveforms of pressure and flow
DIMENSIONS
Height: 12.5 In (31.8 cm)
Width: 8.4 In (21.5 cm)
Depth: 15.2 In (38.5 cm)
Weight: 32 lbs
CONTROLS
Control principle Continuous flow, pressure-limited,time-cycled
Conventional ventilation IMV/IPPV, CPAP
Triggered ventilation IMV, SIPPV, PSV1), Leak adapted
Trigger Flow/volume trigger, Leak adapted
Trigger delay approx. 30 ms
High-Frequency Ventilation 1) 3) CPAP+HFV, IMV+HFV
Frequency 5 to 20 Hz
Volume Guarantee Ventilation) SIMV+VG, SIPPV+VG, PSV+VG
Oxygen mixer loss (bleed flow) 0 (zero) L/min
SETTINGS
Inspiratory Oxygen concentration 21 -100 vol. % oxygen
Peak inspiratory pressure 10 to 80 mbar
PEEP/CPAP 0 to 25 mbar
Maximal frequency 200 bpm2)
Inspiratory time 0.1 to 2 seconds
Expiratory time 0.2 to 30 seconds
Inspiratory flow 1 to 30 L/min
Base flow (VIVE) 1 to 30 L/min
MONITORING
Flow Monitoring at the Y-piece, integrated
Volume Monitoring at the Y-piece, integrated
Lung function monitoring Compliance, resistance C20/C, time constant
FiO2 Monitoring integrated
Real-time curves Flow and pressure, integrated
Inspiratory Oxygen concentration 21 -100 vol. % oxygen
Peak Pressure to 99 mbar
Mean Airway Pressure to 99 mbar
Graphic trends 6 parameters, integrated
Logbook record of last 100 alarms.
We can ship to NATION & WORLDWIDE.
We have more units in stock!
The pictures of the equipment are for reference only. Used medical equipment is constantly being renewed.
ATTENTION: Shipping costs only for Packing & Local Move in Miami to the shipping company. Not including any transportation. Please contact us if you need to know the shipping price. We will be glad to provide you with the best service.
Can Pick UP our equipment from our warehouse.
Good cosmetic condition; no signs of damage or abuse.
For FDA regulations, please, don´t hesitate to contact us.
DISCLAIMER:
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. The item is subject to FDA regulation; I will verify your status as an authorized purchaser of this item before shipping the item.
Didn’t find what you were looking for? Place your own ad on the Bimedis platform
Place your advert on Bimedis and reach buyers worldwide.