Product Details

ModelZeus
BrandDRAGER
CategoryAnesthesia Machines
Posted28.01.2026
Views337

Product Specifications

Anesthesia machine type
Portable
with ventilator
Yes
with temperature control
Yes
with respiratory monitoring
Yes
with low-flow
Yes
with gas scavenging system
Yes
with electronic gas mixer
Yes
MRI-compatible
Yes
Mobile Anesthesia Machines
Yes

Used - Good DRAGER Zeus


Condition:: Used - Good
Year:: 2007
Availability:: In stock
Shipping from:: Germany
Sales area:: Afghanistan, Albania, Algeria


Seller:

pro

Germany

Altan Medical - the national and international trade in used medical equipment and service from reowned manufacturer is our service. A serious and uncomplicated sets us apart. Young machines of the latest generation, which may represent an interesting alternative to a new investment, as well as older models, which are correspondingly cheaper. We are locaded in Emskirchen - Nürnberg Germany.

Description

Anesthesia machine - Ventilator DRÄGER ZEUS SW 3.08

Year 2007 - Serial No. ARYL-0009
Breathing system with APL valve
2 DIVA dosing modules Sevoflurane - Desflurane
Drainage basket CLIC Replacement breathing lime - prevents skin contact
DRÄGER Infinity C500 touchscreen monitor
Dräger VentStar® Anaesthesia Breathing Circuits
With device swivel arm

Technical data:
Gas dosing
Operating modes Fresh gas dosing, auto dosing with insp. O2 control
Fresh gas flow 0.25-18 l/min (fresh gas dosing); 0-18 l/min (auto dosing); closed operating mode (uptake)
O2 control 25-100 %; ORC function
Carrier gases N2O and air
O2 flow > 35 l/min
O2 safety flow 0-12 l/min
Additional O2 flow tube 0-16 l/min (for regional anesthesia)

DIVA anesthetic dosing:
Operating mode with m2 DIVA modules Fresh gas dosing, auto dosing with exsp. anesthetic control ISO,SEV, DES
Filling quantity 315 ml
Dosing range: Fresh gas dosing ISO: 0-5 kPa; SEV: 0-8 kPA; DES: 0-18 kPA
Dosing range: Auto dosing ISO: 0-2.5 kPa; SEV: 0-5 kPA; DES: 0-12 kPA

General Technical data:
Data exchange USB
Serial interface 2 × RS232
Interface for IV system Optional remote control of IV pumps
Ethernet interface (1) For access to the hospital network, network printer or remote inspection
Ethernet interface (2) For access to hospital network printer or for remote inspection
Ethernet interface (3) Infinity network connection
Power supply 100-240 V, 45-65 Hz
Integrated emergency power supply for min. 30, max. 90 minutes
Dimensions (H × W × D) 165 × 110 × 70 cm
Weight 185 kg incl. 2 DIVA modules

Online video viewing via Skype video
We would be delighted to welcome you - more machines in stock
Available immediately - Can be viewed
In stock - Can be tested

Didn’t find what you were looking for? Place your own ad on the Bimedis platform

Place your advert on Bimedis and reach buyers worldwide.

SELL