Product Specifications
- Anterior Chamber Depth, mm
- 1.5 – 6.5
- Lens Thickness, mm
- 5-10
- Measuring
- Haigis, Hoffer Q, Holladay 1 and 2, SRK II, SRK / T
- Frequency, Hz
- 50/60
- Laser class ⓘ
- 1
- Voltage, V ⓘ
- 100-240
Refurbished ZEISS IOL Master V5.4
Condition:: Refurbished
Warranty (month):: 12
Availability:: In stock
Shipping from::
USA
8 998
Safe deal
Bimedis secures your payment until you confirm the equipment is received.
Description
ZEISS IOL MASTER 5.4
We are committed to ensuring our customers’ satisfaction. So here you get more than you came to get. Our policy is OVER-DELIVER! With a differentiated infrastructure and a highly qualified team, composed of technicians and engineers trained in accordance with the highest standards required by manufacturers, We are committed to excellence, development and continuous evolution of its services.
Excellent Cosmetic condition! (no scratches)
Excellent Body condition! (no dents/scratches)
Very tiny cosmetic signs may be visible when viewed very closely Fully Functional Condition! Exceeds 80% of service life
This is a RENEWED unit!! It's in excellent mechanical and cosmetic condition!!
This Zeiss IOL Master 5.4 comes equipped with:
FREE 1 YEAR warranty in the entire USA
Manual
Printer (optional)
Keyboard and Mouse
Dust cover
- Professional packing
The IOLMaster is a combined biometry device for measurements on the human eye required for the preoperative computation of intraocular lens power. It is capable of fast and precise consecutive measurement of the following eye parameters in one session: axial length, corneal curvature, anterior chamber depth and optionally white-to-white. All measurements are non-contact, providing excellent patient comfort. The axial length measurement is based on a patented interference optical method known as partial coherence interferometry (PCI). The displayed results of the axial length measurements are compatible with the ultrasonic immersion measurements of axial length via the use of an internal, statistically verified calculation algorithm. The familiar formulae for IOL calculation can thus be used. Considering the fact that axial length measurements by A-scan ultrasonography (using a standard 10-MHz transducer) have a typical resolution of 0.10 mm to 0.12 mm, axial length measurements by the IOL Master represent a fivefold increase in accuracy. The IOL Master allows fast, accurate measurements of eye length and surface curvature, necessary for cataract surgery. The IOL Master is more efficient because it allows measurements to be taken with complete confidence in the accuracy of the results. Also, because the IOL Master is non-contact (nothing touches the eye itself), there is no need for anesthesia and there is no potential for spread of contamination from the IOLMaster.
Measuring Ranges:
Axial length 14 – 40 mm
Depth of anterior chamber 1.5 – 6.5 mm
Corneal radii 5 – 10 mm
White-to-white 8 – 16 mm
Scaling Displays:
Scaling of display • Axial length 0.01 mm
Corneal radii 0.01 mm
Depth of anterior chamber 0.01 mm
White-to-white 0.1 mm
Formulas for IOL Calculation:
RK II, SRK/T, Holladay, Hoffer Q, Haigis
Clinical history and contact lens fitting method for calculation of the corneal refractive power subsequent to refractive corneal surgery
Haigis-L for IOL calculation for eyes after myopic/hyperopic LASIK/PRK/LASEK
Calculation of phakic anterior and posterior chamber implants
Optimization of IOL constants Interfaces
Interfaces:
Data interface for office management systems
Data export to CD-RW or USB storage media
Provision of data for Holladay IOL Consultant and HIC.SOAP Pro
Ethernet port for network connection and network printer
Compliance with HIPAA directive (USA only)in regard to user authentification and identification
We are committed to ensuring our customers’ satisfaction. So here you get more than you came to get. Our policy is OVER-DELIVER! With a differentiated infrastructure and a highly qualified team, composed of technicians and engineers trained in accordance with the highest standards required by manufacturers, We are committed to excellence, development and continuous evolution of its services.
Excellent Cosmetic condition! (no scratches)
Excellent Body condition! (no dents/scratches)
Very tiny cosmetic signs may be visible when viewed very closely Fully Functional Condition! Exceeds 80% of service life
This is a RENEWED unit!! It's in excellent mechanical and cosmetic condition!!
This Zeiss IOL Master 5.4 comes equipped with:
FREE 1 YEAR warranty in the entire USA
Manual
Printer (optional)
Keyboard and Mouse
Dust cover
- Professional packing
The IOLMaster is a combined biometry device for measurements on the human eye required for the preoperative computation of intraocular lens power. It is capable of fast and precise consecutive measurement of the following eye parameters in one session: axial length, corneal curvature, anterior chamber depth and optionally white-to-white. All measurements are non-contact, providing excellent patient comfort. The axial length measurement is based on a patented interference optical method known as partial coherence interferometry (PCI). The displayed results of the axial length measurements are compatible with the ultrasonic immersion measurements of axial length via the use of an internal, statistically verified calculation algorithm. The familiar formulae for IOL calculation can thus be used. Considering the fact that axial length measurements by A-scan ultrasonography (using a standard 10-MHz transducer) have a typical resolution of 0.10 mm to 0.12 mm, axial length measurements by the IOL Master represent a fivefold increase in accuracy. The IOL Master allows fast, accurate measurements of eye length and surface curvature, necessary for cataract surgery. The IOL Master is more efficient because it allows measurements to be taken with complete confidence in the accuracy of the results. Also, because the IOL Master is non-contact (nothing touches the eye itself), there is no need for anesthesia and there is no potential for spread of contamination from the IOLMaster.
Measuring Ranges:
Axial length 14 – 40 mm
Depth of anterior chamber 1.5 – 6.5 mm
Corneal radii 5 – 10 mm
White-to-white 8 – 16 mm
Scaling Displays:
Scaling of display • Axial length 0.01 mm
Corneal radii 0.01 mm
Depth of anterior chamber 0.01 mm
White-to-white 0.1 mm
Formulas for IOL Calculation:
RK II, SRK/T, Holladay, Hoffer Q, Haigis
Clinical history and contact lens fitting method for calculation of the corneal refractive power subsequent to refractive corneal surgery
Haigis-L for IOL calculation for eyes after myopic/hyperopic LASIK/PRK/LASEK
Calculation of phakic anterior and posterior chamber implants
Optimization of IOL constants Interfaces
Interfaces:
Data interface for office management systems
Data export to CD-RW or USB storage media
Provision of data for Holladay IOL Consultant and HIC.SOAP Pro
Ethernet port for network connection and network printer
Compliance with HIPAA directive (USA only)in regard to user authentification and identification
Didn’t find what you were looking for? Place your own ad on the Bimedis platform
Place your advert on Bimedis and reach buyers worldwide.